11.7

EncoderControl

Name
EncoderSelector
EncoderSourceA [EncoderSelector]
EncoderSourceB [EncoderSelector]
EncoderMode [EncoderSelector]
EncoderDriver [EncoderSelector]
EncoderOutputMode [EncoderSelector]
EncoderStatus [EncoderSelector]
EncoderTimeout [EncoderSelector]
EncoderResetSource [EncoderSelector]
EncoderResetActivation [EncoderSelector]
EncoderReset [EncoderSelector]
EncoderValue [EncoderSelector]
EncoderValueAtReset [EncoderSelector]
11.8

LogicBlockControl

Name
LogicBlockSelector
LogicBlockFunction [LogicBlockSelector]
LogicBlockInputNumber
[LogicBlockSelector]
LogicBlockInputSelector
[LogicBlockSelector]
LogicBlockInputSource
[LogicBlockSelector]
[LogicBlockInputSelector]
LogicBlockInputInverter
[LogicBlockSelector]
[LogicBlockInputSelector]
FS-C4KU7DGES-F / FS-C4KU7DGES-M42 / FS-C2KU7DGES-F / FS-C2KU7DGES-M42 / FS-C2KU7DGES-C
Product Specifications and Use's Guide
Description
Selects which Encoder to configure.
Selects the signal which will be the source of the A input of the
Encoder.
Selects the signal which will be the source of the B input of the
Encoder.
Selects if the count of encoder uses FourPhase mode with jitter filtering
or the HighResolution mode without jitter filtering.
Sets how many Encoder increment/decrements are needed to
generate an Encoder output pulse signal.
Selects the conditions for the Encoder interface to generate a valid
Encoder output signal.
Returns the motion status of the encoder.
Sets the maximum time interval between encoder counter increments
before the status turns to static.
Selects the signals that will be the source to reset the Encoder.
Selects the Activation mode of the Encoder Reset Source signal.
Does a software reset of the selected Encoder and starts it.
Reads or writes the current value of the position counter of the
selected Encoder.
Reads the value of the of the position counter of the selected Encoder
when it was reset by a signal or by an explicit EncoderReset
command.
Description
Specifies the Logic Block to configure.
Selects the combinational logic Function of the Logic Block to
configure.
Specifies the number of active signal inputs of the Logic Block.
Selects the Logic Block's input to configure.
Selects the source signal for the input into the Logic Block.
Selects if the selected Logic Block Input source signal is inverted.