10.12
Counter And Timer Control
Controls "Timer" and "Counter".
Timer Control
GenICam Parameters
TimerSelector
TimerDuration
TimerDelay
TimerValue
TimerTriggerSource
TimerTriggerActivation
When the timing of "Timer0active" signal is adjusting to active signal of Exposure, "Timer0" can be used as
strobe control signal.
Counter Control
GenICam Parameters
CounterSelector
CounterEventSource
CounterResetSource
CounterResetActivation
CounterReset
CounterValue
FS-C4KU7DGES-F / FS-C4KU7DGES-M42 / FS-C2KU7DGES-F / FS-C2KU7DGES-M42 / FS-C2KU7DGES-C
Product Specifications and Use's Guide
IEnumeration
Setup timer selection
Type
Selection: Timer0, Timer1
Default: Timer0
IFloat Type
Duration of "Timer active" signal (in µsecond)
Range: 1 to
Default: 1
IFloat Type
Delay for "Timer active" signal (in µsecond)
Range: 0 to
Default: 0
IFloat Type
Returns value for "Timer active" signal
IEnumeration
Reference signal selection to generate "Timer active" signal
Type
Selection: Off, Line0, Line1, Line2, FrameTrigger,
Default: Off
IEnumeration
Polarity of reference signal to generate "Timer active" signal
Type
Selection: RisingEdge, FallingEdge
Default: RisingEdge"
IEnumeration
Counter selection
Type
Selection: Counter0, Counter1
Default: Counter0
IEnumeration
Counter event source selection
Type
Selection: Off, FrameStart, FrameTrigger
Default: Off
IEnumeration
Reference signal selection to reset counter
Type
Selection: Off, Line0, Line1, Line2
Default: Off
IEnumeration
Polarity of reference signal to reset counter
Type
Selection: RisingEdge, FallingEdge
Default: RisingEdge
ICommand Type
Reset switch
Activate as switch when selecting "Software" at "CounterResetSource"
IInteger Type
Returns number of counter
4,294,967,295
4,294,967,295
ExposureStart, AcquisitionTrigger, SoftwareSignal0,
"oftwareSignal1, LogicBlock0, Action0
No.20S046-00