11.5

DigitalIOControl

Name
LineSelector
LineMode [LineSelector]
LineInverter [LineSelector]
LineStatus [LineSelector]
LineStatusAll
LineSource [LineSelector]
LineFormat [LineSelector]
LineDebounceTime [LineSelector]
UserOutputSelector
UserOutputValue [UseOutputSelector]
11.6

CounterAndTimerControl

Name
CounterSelector
CounterEventSource [CounterSelector]
CounterResetSource [CounterSelector]
CounterResetActivation [CounterSelector]
CounterReset [CounterSelector]
CounterValue [CounterSelector]
TimerSelector
TimerDuration [TimerSelector]
TimerDelay [TimerSelector]
TimerValue [TimerSelector]
TimerTriggerSource [TimerSelector]
TimerTriggerActivation [TimerSelector]
FS-C4KU7DGES-F / FS-C4KU7DGES-M42 / FS-C2KU7DGES-F / FS-C2KU7DGES-M42 / FS-C2KU7DGES-C
Product Specifications and Use's Guide
Description
Selects the physical line (or pin) of the external device connector or the
virtual line of the Transport Layer to configure.
Controls if the physical Line is used to Input or Output a signal.
Controls the inversion of the signal of the selected input or output Line.
Returns the current status of the selected input or output Line.
Returns the current status of all available Line signals at time of polling
in a single bitfield.
Selects which internal acquisition or I/O source signal to output on the
selected Line.
Controls the current electrical format of the selected physical input or
output Line.
Sets the value of the input line debouncer time.
Selects which bit of the User Output register will be set by User Output
Value.
Sets the value of the bit selected by User Output Selector.
Description
Selects which Counter to configure.
Select the events that will be the source to increment the Counter.
Selects the signals that will be the source to reset the Counter.
Selects the Activation mode of the Counter Reset Source signal.
Does a software reset of the selected Counter and starts it.
Reads or writes the current value of the selected Counter.
Selects which Timer to configure.
Sets the duration (in microseconds) of the Timer pulse.
Sets the duration (in microseconds) of the delay to apply at the
reception of a trigger before starting the Timer.
Reads or writes the current value (in microseconds) of the selected
Timer.
Selects the source of the trigger to start the Timer.
Selects the activation mode of the trigger to start the Timer.
No.20S046-00