9.4

Edge preset trigger mode (Trigger input while exposing or image is out)

In this trigger mode with positive polarity, the expose starts at rising edge of trigger signal.
The exposure duration time is based on the preset exposure setting stored by camera setting communication.
In this trigger mode with negative polarity, the expose starts at falling edge of trigger signal.
The exposure duration time is based on the preset exposure setting stored by camera setting communication.
However, if the trigger signal input while exposing with previous trigger signal, resets exposing and exposing
starts with newer trigger signal.
If the trigger signal input while output image with previous trigger signal, image is output and exposing starts
with newer trigger signal.

Timing of edge preset trigger mode (Trigger input while exposing or image is out)

Trigger Signal
(Positive polarity)
Expose
Image out
*Note: The exposure time is preset "ExposureTime" on GenICam setting.