10.14
Logic Block Control
The trigger signal generating with more than two input signals at Logic circuit.
GenICam Parameters
LogicBlockSelector
LogicBlockFunction
LogicBlockInputNumber
LogicBlockInputSelector
LogicBlockInputSource
LogicBlockInputInverter
FS-C4KU7DGES-F / FS-C4KU7DGES-M42 / FS-C2KU7DGES-F / FS-C2KU7DGES-M42 / FS-C2KU7DGES-C
Product Specifications and Use's Guide
IEnumeration
Selects setup LogicBlock
Type
Selection: LogicBlock0
Default: LogicBlock0
IEnumeration
Selects logic circuit of LogicBlock0
Type
Selection: AND, OR
Default: OR
IInteger Type
Selects number of input signal for LogicBlock0
Range: 2 to 4
Default: 2
IInteger Type
Selects input signal for LogicBlock0
Range: 0 to 3
Default: 0
Note. The range will be change with setting of LogicBlockInputNumber
IEnumeration
Selects signal type for input signal that selected at
Type
LogicBlockInputSelector
Selection: True, False, SoftwareSignal0, SoftwareSignal1,
Default: True
IEnumeration
Inverts polarity of input signal that selected at LogicBlockInputSelector
Type
Selection: False (no invert), True (invert)
Default: False
Line0, Line1, Line2
No.20S046-00