11.1 MAINTENANCE
The Extend-A-Gun requires little maintenance. The Extend-A-Gun should be kept clean and free of dirt. All controls should be checked
for freedom of movement and proper operation before each use. Any inoperable or damaged parts should be repaired or replaced
immediately. Consult factory for recommended service procedure.
11.2 LUBRICATION
The Extend-A-Gun is permanently lubricated on the cup seal. If lubricant has been removed during service, apply a thin film of White
Lithium Grease on seal surfaces.
12.0 TROUBLE SHOOTING
SYMPTOM
Leaks
Binding,
Erratic Operation
Does Not Raise
Does Not Lower
12.1 REPAIR
Factory service is available with repair time seldom exceeding one day in our facility. Factory serviced equipment is repaired by
experienced technicians, wet tested to original specifications, and promptly returned. Any returns should include a note as to the nature
of the problem and whom to reach in case of questions.
Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability for
damage to equipment or injury to personnel that is a result of user service. Contact the factory or visit the web site at tft.com for parts
lists, exploded views, test procedures and troubleshooting guides.
Performance tests shall be conducted on the equipment after a repair, or anytime a problem is reported to verify operation in accordance
with TFT test procedures. Consult factory for the procedure that corresponds to the model and serial number of the equipment. Any
equipment which fails the related test criteria should be removed from service immediately. Troubleshooting guides are available with
each test procedure or equipment can be returned to the factory for service and testing.
CAUTION
NOTICE
13.0 EXPLODED VIEW AND PARTS LIST
Exploded view and parts list are available at tft.com/serial-number.
TASK FORCE TIPS LLC
MADE IN USA · tft.com
©Copyright Task Force Tips LLC 2004-2020
POSSIBLE CAUSE
Debris or damage in seal area
Low Voltage (see below)
Low voltage due to:
- wire gage too small
- wire length too long
- poor connection
- inadequate apparatus electrical system
Mechanical Binding
- damage to chain drive
Low voltage due to:
- wire gage too small
- wire length too long
- poor connection
- inadequate apparatus electrical system
Mechanical Binding
- damage to chain drive
Monitor not in PARK position
Any alterations to the product or its markings could diminish safety and constitutes a misuse of
this product.
All replacement parts must be obtained from the manufacturer to assure proper operation of the
device.
REMEDY
Clean out debris or replace damaged parts
See Below
Check connections and wiring
Verify voltage is above 10 volts at the control box,
while operating
Use manual override to verify mechanical operation.
Consult Factory
Check connections and wiring
Verify voltage is above 10 volts at the control box,
while operating
Use manual override to verify mechanical operation
Perform Monitor PARK operation
Consult Factory
Table 12.0