Redundant Server Pc - Bosch DICENTIS Hardware Installation Manual

Hide thumbs Also See for DICENTIS:
Table of Contents

Advertisement

DICENTIS
4.4.2

Redundant server PC

System availability can be improved by connecting a redundant DICENTIS server PC and the
associated components and cables to the DICENTIS Conference System. The maximum
number of Ethernet devices in the largest possible loop (including the root switch) is 22.
The total number of devices allowed in a loop depends on:
The figure shows how to calculate the number of devices in the loop. The grey line shows the
largest loop. The # sign shows the way the devices are counted.
In the example below up to 17 (22 - 5 = 17) devices can be connected.
Figure 4.8: Redundant DICENTIS server PC with redundant components and cables
For this option to work the DICENTIS Conference System has to be run in combination with
EverRun Enterprise software from Stratus Technologies. For more information, refer to the
Stratus Technologies website.
Other options that can be used for guaranteeing the reliability of the DICENTIS Conference
System include:
Bosch Security Systems B.V.
The type of device connected in the loop (for example, DCNM-MMD2 devices consume
more power than DCNM-DE devices).
The length of the loop (cable also consumes power).
1 DICENTIS system
3 DCNM-APS2
5 DICENTIS cabling (redundant loop)
Remote SQL servers.
Hardware Installation Manual
System installation design and planning | en
2 Network switch (with optional
redundant power supply)
4 DCNM-PS2
31
2021.01 | V2.2 |

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents