Tab. 5.8: Connector pinout
Note: the female plug to be used with the 8-pin connector is supplied pre-assembled with the
product. You will need to make the wire connections, which only require simple push-in action
to lock.
Wiring
The connection to the Phoenix connector has to be made using ferrules.
The tables below give more details on the connection.
Conductor cross section max.
(solid and flexible)
Conductor cross section flexible,
with ferrule without plastic sleeve
max.
Conductor cross section flexible,
with ferrule with plastic sleeve
max.
Tab. 5.9: Connection data
Ferrules without insulating collar
(according to DIN 46228-1)
Tab. 5.10: Specifications for ferrules
Bosch Security Systems B.V.
Pin #
Function
1
Switch to set the
booth on-air LED on/
2
off
3
4
5
Input for an external
telephone system
6
ringing indicator
7
Input for an external
system for warning
8
indicator
Hardware Installation Manual
Specifications
50 V/1 A potential free
contact
Galvanic separated
inactive: < 1 VDC
active: > 3 VDC
max.: 24 VDC
Galvanic separated
inactive: < 1 VDC
active: > 3 VDC
max.: 24 VDC
Galvanic separated
2
1.5 mm
2
1.5 mm
2
0.75 mm
Cross section: 0.22 mm
Length: 5 mm to 10 mm
Installation material and tools | en
Description
OUTPUT
OUTPUT
INPUT Negative ( - )
INPUT Positive ( + )
INPUT Negative ( - )
INPUT Positive ( + )
2
2
to 1.5 mm
2021.01 | V2.2 |