User Manual (Mexico Edition)
No.
Parameter
7
Grid reconnection
voltage lower limit
8
Grid reconnection
frequency upper limit
9
Grid reconnection
frequency lower limit
10
Reactive power
compensation (cosφ-
P) trigger voltage
11
Reactive power
compensation (cosφ-
P) exit voltage

7.2.2.2 Setting Protection Parameters

Procedure
Step 1 Choose Function Menu > Settings > Protection Parameters to access the
settings screen.
Issue 06 (2020-10-12)
Description
The standards of certain countries and regions
require that the SUN2000 must not export
power to the power grid again when the grid
voltage is below the value of Grid
reconnection voltage lower limit after the
SUN2000 shuts down due to a fault.
The standards of certain countries and regions
require that the SUN2000 must not export
power to the power grid again when the grid
frequency exceeds the value of Grid
reconnection frequency upper limit after the
SUN2000 shuts down due to a fault.
The standards of certain countries and regions
require that the SUN2000 must not export
power to the power grid again when the grid
frequency is below the value of Grid
reconnection frequency lower limit after the
SUN2000 shuts down due to a fault.
Specifies the voltage threshold for triggering
reactive power compensation based on the
cosφ-P curve.
Specifies the voltage threshold for exiting
reactive power compensation based on the
cosφ-P curve.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Unit
V
Hz
Hz
%
%
85