Step 3 (Optional) To enhance the corrosion resistance of a ground terminal, apply silica
gel or paint around the terminal.
----End
Installing the AC Output Power Cable
Step 1 Remove the locking cap from the AC OUTPUT cable gland and then remove the
plug.
Step 2 Route the cable through the cable gland.
1. Select appropriate rubber fittings based on the outer diameter of the AC power
2. To avoid damaging the rubber fitting, do not route a cable with a crimped OT
3. Adjusting a cable when the thread-lock sealing nut is tightened will shift the
Figure 5-8 Routing a cable
Step 3 Remove an appropriate length of the jacket and insulation layer from the AC
output power cable using a wire stripper.
Ensure that the jacket is in the maintenance compartment.
Issue 06 (2020-10-12)
NO TICE
cable to ensure proper sealing.
terminal directly through the rubber fitting.
rubber fitting, which will affect the Ingress Protection Rating of the device.
NO TICE