REPLACING THE POWER SUPPLY

4

TOOLS NEEDED

2 mm Hex Driver
3 mm Hex Driver
#2 Phillips Screwdriver
REPLACING THE POWER SUPPLY
WARNING: BEFORE SERVICING THESE COMPONENTS, ENSURE YOU ARE WEARING A WELL-GROUNDED
ELECTRO-STATIC DISCHARGE (ESD) STRAP. ESD PROTECTION IS REQUIRED.
WARNING: NEVER PULL ON WIRES TO DISCONNECT THE CONNECTORS. THIS COULD DAMAGE THE WIRES
AND THE CONNECTORS AND VOID THE MANUFACTURER'S WARRANTY.
WARNING: EVEN AFTER THE PRINTER HAS BEEN TURNED OFF AND DISCONNECTED FROM UTILITY POWER, IT
IS POSSIBLE TO STILL CONTAIN RESIDUAL VOLTAGE. EXTREME CAUTION IS REQUIRED.
1.
Remove all print cartridges and the jet wiper assembly.
NOTE: Refer to the section titled Replacing A Material Cartridge in
chapter 6 of the User Guide.
Print Pad Calibration
2.
Navigate to the
PLATE.
3.
Once the print pad has raised, turn off the main power switch on the
right side of the printer.
4.
Disconnect the power cord from the printer.
WARNING: THE PRINTER MUST BE DISCONNECTED FROM
UTILITY POWER BEFORE PROCEEDING.
5.
Using a 3 mm hex head driver, loosen and remove all nine (9)
3mm hex head bolts securing the inner floor. Retain the screws for
reassembly.