AE Techron 7548 Operator's Manual page 42

Single-channel industrial amplifiers for demanding, high-power systems
Hide thumbs Also See for 7548:
Table of Contents

Advertisement

Pin #
Function
Description
20
I SUM1–
Multiple Amplifier 
Summing, Ampli-
fier 1
21
I SUM2–
Multiple Amplifier 
Summing, Ampli-
fier 2
22
I SUM3–
Multiple Amplifier 
Summing, Ampli-
fier 3
23
OverLoad Out
Overload output 
(amplifier output is 
clipping).
24
OverVoltage 
Overvoltage output 
Out
(High AC line volt-
age).
25
Reset
Reset
Gray shaded areas indicate pin not used / feature not implemented.
Signal
Level when
Level when
Type
Asserted
Deasserted
DC
DC
DC
DC
–24V
0V
DC
–24V
0V
DC
–15V
0V
Notes
Planned for use in multiple amplifier 
configurations - paralleled and run-
ning Controlled Current Mode
Planned for use in multiple amplifier 
configurations - paralleled and run-
ning Controlled Current Mode
Planned for use in multiple amplifier 
configurations - paralleled and run-
ning Controlled Current Mode
When amp is normal, this pin
is pulled to –24V through a 
47.5K-ohm resistor; when amp is in
Overload state, this pin is ground-
ed. Do not exceed 6 milliamps.
When amp is normal, this pin
is pulled to –24V through a 
47.5K-ohm resistor; when amp
is in Overvoltage state, this pin 
is grounded. Do not exceed 6 
milliamps.
Tie to PIN 13 (–24V dc) and create 
a –15V dc source; <2mA required 
for reset. Connect the –15V dc 
source to PIN 25 (Reset) through a 
1K buffer resistor to reset.
Blue shaded areas indicate used only in multi-amplifier systems.
Applications
Currently not used.
Currently not used.
Currently not used.
Remote Signal of Overload Condition: LED, when lit, 
signals Overload condition. Use a 6mA series resistor 
of 4.7K-ohm for LED or OPTO, tie to –24V source (PIN 
13).
Remote Signal of Overvoltage Condition: LED, when 
lit, signals Overvoltage condition. Use a 6mA series re-
sistor of 4.7K-ohm for LED or OPTO, tie to –24V source 
(PIN 13).
Reset from Standby: Use a dry contact switch and 
voltage regulator to return amp to Ready/Run condition 
after Overload conditions. Assert –15V for at least 100 
ms to clear error condition.