3 Amplifier Operation

3.1 Front-Panel Controls & Display
This section provides an overview of Front-
Panel controls and display screen found on the
7548/7794/7796/7796HC amplifier. Please refer to 
Figure 3.1 for item locations.
3.1.1 Input Buttons
Three Push Buttons on the amplifier front panel 
control basic operation of the amplifier. 
Enable – For stand-alone amplifiers, Enable will 
release the amplifier from Stop mode and place 
the amplifier in Run mode (both Ready and Run 
LEDs will be lit). When the amplifier is placed 
in Run mode, the amplifier will amplify the input 
signal. If an amplifier is disabled using a Remote 
Standby application, the amplifier will be placed in 
Standby mode (both Ready and Standby LEDs will 
be lit). To return the amplifier to Run mode, release 
the Standby condition using the remote switch. 
See the Applications section of this manual for
more information on remote amplifier operation.
In multi-amp systems that have been configured to 
start up in Standby mode, when the Enable button
is pressed on one amplifier, the amplifier will be 
placed in Standby mode and remain in Standby
mode until all amplifiers in the system have been 
Enabled. The system will automatically proceed
to Run mode when all amplifiers in the system 
achieve Standby mode.
12
7548/7794/7796/7796HC OPERATOR'S MANUAL – SECTION 3
Figure 3.1 – Front Panel Controls and Display
Information subject to change
Stop – For stand-alone amplifiers, Stop will place 
the amplifier in Stop mode (both Standby and Stop 
LEDs will be lit). When the amplifier is part of a 
multi-amp system, pressing the Stop button on any 
amplifier in the system will place that amplifier in 
Stop mode and all other amplifiers in the system 
in Standby mode. When an amplifier is in Stop or 
Standby mode, the low-voltage transformer is en-
ergized but the high-voltage transformers are not. 
Reset – For stand-alone amplifiers, when a fault 
condition occurs, the amplifier may be placed in 
Standby mode (Standby LED will be lit), depending 
on the amplifier configuration and the fault condi-
tion. To release the amplifier from Standby mode, 
clear the fault condition and then press the Reset
button. If the amplifier is in Run mode when the 
fault condition occurs, pressing the Reset button 
will return the amplifier to Run mode. If the amplifi-
er is in Stop mode when the fault condition occurs,
pressing the Reset button will return the amplifier 
to Stop mode.
When the amplifier is part of a multi-amp system, 
pressing the Reset button on the amplifier report-
ing the fault condition will clear the condition and 
return all amplifiers to Run or Stop mode; pressing 
the Reset button on other amplifiers in the system 
will NOT clear the fault condition.