Pin #
Function
Description
10
Sampled
Amp Analog 
Common
Ground; Blanking 
Ground
11
OverTemp 
Over-temperature 
Out
output
12
Run
Amplifier Run output DC
13
–24V
–24V Power Output
14
Common
Ground before 
Sense Resistors
15
–1 IN
Differential Follower 
Input
16
+24V
+24V Power Output
17
Digital Ground Digital circuitry 
ground - Interlock 
Common
18
OEM App
Input Monitor (OEM 
only)
19
I MON – 
Differential Current 
(alt.: OEM 
Monitor – ;
App)
(- Input Monitor, 
OEM only)
Signal
Level when
Level when
Type
Asserted
Deasserted
DC
–24V
0V
–24V
0V
DC
AC or
Up to 200V 
0V
DC
peak
DC
DC
0V
0V
7212/7224/
AC or
DC
7226: 5A/V   
7548/7794/
7796/7796HC:
20A/V
Notes
Amplifier ground.
When amp is normal, this pin
is pulled to –24V through a 
47.5K-ohm resistor; when amp is in
OverTemp state, this pin is ground-
ed. Do not exceed 7 milliamps.
When amp is in Standby mode, this
pin is pulled to –24V; when amp is 
in Run mode, this pin is grounded,  
energizing Mains Relays and allow-
ing drive for an external LED. 
DO NOT exceed 7mA; DO NOT 
ground this pin as this will enable 
Main Power Relays.
–24V dc, 30 mA max
Current monitor reference. Voltage 
between Common and Sampled
Common is voltage on the Current 
Sense resistor.
Only used in multiple amplifier 
configurations, Series mode.
+24V dc, 30 mA max.
Used to monitor the input signal 
from an OEM DAC card; this is the 
actual input signal.
Inverted I MON+ (PIN 6). Output 
current produced per voltage 
detect.
Applications
Can be used as Blanking return or as a reference of the 
amplifier for status reporting applications. See Over-
Temp (PIN 11), Run (PIN 12), Overload (PIN 23), and 
OverVoltage (PIN 24).
Remote Signal of Over-Temperature Condition: LED, 
when lit, signals Over Temperature condition. Use a 6 
mA series resistor of 4.7K-ohm for LED or OPTO, tie to 
–24V source (PIN 13).
Remote Signal of Run Condition: LED, when lit, sig-
nals Run state. Use a 6mA series resistor of 4.7K-ohm 
for LED or OPTO, tie to –24V source (PIN 13).
Internally tied for use in status reporting applications. 
See OverTemp (PIN 11), Run (PIN 12), Overload (PIN 
23), and OverVoltage (PIN 24).
Possibly series amplifiers will not need current reporting 
on the High side amp, since its current will be same as 
Master.
Can accept output of PIN 1 (Amplifier Output) OR PIN 
2 (Sampled Common) from Master device when in 
Follower mode.
Used in status reporting applications. See OverTemp 
(PIN 11), Run (PIN 12), Overload (PIN 23), and Over-
Voltage (PIN 24).
Used with PIN 25 (Reset) for Remote Reset from 
Standby or Stop after Error. Used with PIN 4 (Interlock) 
for simultaneous remote to Standby of all amps in a
multi-amplifier system.
OEM modification only; normally no connection.
Current Monitoring: Connect a voltage meter to 
monitor the output current being produced by the 
amplifier. For each 1V detected, current output is 5A 
(7212/7224/7226) or 20A (7548/7794/7796/7796HC).