7548/7794/7796/7796HC OPERATOR'S MANUAL – SECTION 8
AC Power: A toggle switch circuit breaker opens all 
legs of the AC mains on excess current demand. 
7548: Three-phase, 208V AC (±10%), 47-60 Hz,  
  20A AC service (400V AC (±10%), 15A version  
  available).
7794 and 7796: Three-phase, 208V AC (±10%),  
  47-60 Hz, 30A AC service (400V AC (±10%), 15A  
  version available).
7796HC: Three-phase, 208V AC (±10%), 47-60 
  Hz, 30A AC service (400V AC version NOT 
  available).
Operating Temperature: 10°C to 50°C (50°F to 
122°F), Maximum Output Power de-rated above 
30°C (86°F)
97-7796264_09-04-2020
Humidity: 70% or less, non-condensing
Cooling: Forced air-cooling from front to back 
through removable filters via four (7548) or six 
(7794/7796/7796HC) 100 ft3/min. fans. No space is 
required between rack-mounted amplifiers. Air filters 
are removable from the rear via one fastener per side
and may be eliminated if cabinet filtration is provided.
Dimensions:
7548: 19" x 22.8" x 8.75" (48.3 cm x 57.9 cm x 22.2  
  cm). Unit occupies 5 - EIA 19-inch wide rack units.
7794, 7796 and 7796HC: 19" x 22.8" x 12.25"   
  (48.3 cm x 57.9 cm x 31.1 cm). Unit occupies 7 -  
EIA 19-inch wide rack units.
Information subject to change