4.1 Thermal Design

A parameter that has to be kept in very high consideration is the thermal design of the system.
Highly integrated modules, like Q7-C26 module, offer to the user very good performances in minimal spaces, therefore allowing the systems' minimisation. On the
counterpart, the miniaturising of IC's and the rise of operative frequencies of processors lead to the generation of a big amount of heat, that must be dissipated to
prevent system hang-off or faults.
®
Qseven
specifications take into account the use of a heatspreader, which will act only as thermal coupling device between the Qseven
dissipating surface/cooler. The heatspreader also needs to be thermally coupled to all the heat generating surfaces using a thermal gap pad, which will optimise the
heat exchange between the module and the heatspreader.
The heatspreader is not intended to be a cooling system by itself, but only as means for transferring heat to another surface/cooler, like heatsinks, fans, heat pipes
and so on.
Conversely, heatsinks in some situation can represent the cooling solution. Indeed, when using Q7-C26 module, it is necessary to consider carefully the heat
generated by the module in the assembled final system, and the scenario of utilisation.
Until the module is used on a development Carrier board, on free air, just for software development and system tuning, then a finned heatsink could be sufficient for
module's cooling. Anyhow, please remember that all depends also on the workload of the processor. Heavy computational tasks will generate much heat with all
processor versions.
Therefore, it is always necessary that the customer study and develop accurately the cooling solution for his system, by evaluating processor's workload, utilisation
scenarios, the enclosures of the system, the air flow and so on. This is particularly needed for industrial grade modules.
SECO can provide Q7-C26 specific heatspreaders and heatsinks, but please remember that their use must be evaluated accurately inside the final system, and that
they should be used only as a part of a more comprehensive ad-hoc cooling solutions.
Ordering Code
Description
QC26-DISS-1-PK
Q7-C26 Heat Spreader (Passive)
QC26-DISS-2-PK
Q7-C26 Heatsink (Passive)
QC26-DISS-2-PK
Q7-C26 Heatsink (Active)
Q7-C26
Q7-C26 User Manual - Rev. First Edition: 1.0 - Last Edition: 1.0
Author: A.R - Reviewed by S.R. - Copyright © 2020 SECO S.p.A
®
module and an external
43

Advertisement

Table of Contents
loading

Table of Contents