Mitsubishi Electric FR-E700EX Manual page 4

Sensorless servo
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Line up
Drive unit
 Model
FR - E720EX - 0.75 K
Symbol
Voltage class
Symbol
Drive unit capacity
Three-phase
Represents
E720EX
0.1 to 0.75
200V class
the capacity (kW).
Drive unit model
0.1
0.2
0.4
FR-E720EX-K
Motor
 Model
MM - GKR 1 3
Symbol
Rated output (kW)
Symbol
Rated speed (r/min)
1
0.1
3
3000
2
0.2
4
0.4
7
0.75
*1: The reduction gear equipped models do not have the oil seal.
*2: The motor with the oil seal has an outline dimension different from the standard motor.
For the details, please contact your sales representative.
*3: For the applicable models and detailed specifications, refer to page 10.
*4: For the applicable models and detailed specifications, refer to page 13.
Motor model
13
23
43
73
MM-GKR
: Available
5
Compatible with UL
cUL
(UL 508C),
(CSA C22.2 No.14)
EC Directives
, Radio Waves Act
(CE marking)
Being RoHS compliant, the FR-E700EX series drive units
are friendly to people and to the environment.
0.75
: Available
Symbol
Oil seal
Symbol
Reduction gear
*3
Symbol
Not used
Not used
Standard (straight shaft)
J
Used
*1*2
General industrial
Shaft with keyway
K
G0
machine supported
(with or without key)
(flange installation)
D
Compatible with UL
(UL1004-1/UL1004-6),
CSA
, EC Directives
(CSA C22.2 No.100)
(CE marking)
Being RoHS compliant, the MM-GKR series motors
are friendly to people and to the environment.
Connection example
,
(South Korea)
Shaft end
AC reactor (FR-HAL)
*4
Refer to page 37
D-cut shaft
*4
Noise filter (ferrite
core)*
(FR-BSF01, FR-BLF)
Refer to page 39
*: Filterpack (FR-BFP2), which contains DC reactor and noise filter in one package, is also available.
High power factor
converter (FR-HC2)
Refer to page 41
: Install these options as a required.
S e n s o r
AC power supply
Use within the permissible
power supply
specifications of the drive unit.
Enclosure surface operation panel (FR-PA07)
Refer to page 37
Moulded case circuit breaker
(MCCB) or earth leakage circuit
Parameter unit
breaker (ELB), fuse
(FR-PU07)
The breaker must be selected carefully
Refer to page 25
since an inrush current flows in the
drive unit at power on.
Refer to page 43
Magnetic contactor (MC)
Install the magnetic contactor to ensure
safety. Do not use this magnetic
contactor to start and stop the drive
unit. Doing so will cause the drive unit
life to be shorten.
Refer to page 43
DC reactor
(FR-HEL)*
Refer to page 38
Drive unit
(FR-E700EX)
P/+
P1
R/L1 S/L2 T/L3
(Ground)
Noise filter
(capacitor)*
(FR-BIF)
Refer to page 38
Power regeneration
Brake unit
common converter (FR-CV)
(FR-BU2)
Refer to page 41
Refer to page 40
l e s s
S e r v o
USB connector
A personal computer and a drive unit can be
connected with a USB (Ver1. 1) cable.
Parameter setting and monitoring can be
performed by FR Configurator (FR-SW3-SETUP-
W) (will be supported soon).
Refer to page 26
Brake resistor (FR-ABR, MRS type)
Refer to page 40
P/+
PR
U
V
W
Noise filter (ferrite core)
(FR-BSF01, FR-BLF)
Refer to page 39
Magnetic motor starter
Earth
Example) No-fuse switch
(DSN type)
Install a contactor in an application
P/+
N/-
where the PM motor is driven by
the load even at power-OFF of the
drive unit. Do not open or close
the magnetic motor starter while
the drive unit is running (outputting).
Refer to page 46
Power supply cable
(Servo motor power supply cable (option))
Refer to page 42
Motor (MM-GKR)
Devices connected to the output
Do not install a power factor correction capacitor, surge
suppressor or noise filter (capacitor) on the output side of the
drive unit. When installing a moulded case circuit breaker on
the output side of the drive unit, contact each manufacturer
for selection of the moulded case circuit breaker.
Earth (Ground)
To prevent an electric shock, always earth (ground) the motor
and drive unit.
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mm-gkr

Table of Contents