Function Parameter
52
DU/PU main display data selection
54
FM terminal function selection
55
Speed monitoring reference
56
Current monitoring reference
—
59
Remote function selection
—
65
Retry selection
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
—
70
Special regenerative brake duty
—
73
Analog input selection
—
74
Input filter time constant
Reset selection/disconnected PU
—
75
detection/PU stop selection
—
77
Parameter write selection
—
78
Reverse rotation prevention selection
—
79
Operation mode selection
110
Acceleration time for home position return 0.01 to 360s
111
Deceleration time for home position return 0.01 to 360s
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time
124
PU communication CR/LF selection
—
125
Terminal 2 speed setting gain speed
—
126
Terminal 4 speed setting gain speed
127
PID control automatic switchover speed
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
—
144
Speed setting switchover
Acceleration/deceleration time switching
—
147
speed
150
Output current detection level
151
Output current detection signal delay time 0 to 10s
152
Zero current detection level
153
Zero current detection time
—
156
Torque limit selection
—
157
OL signal output timer
—
160
Extended function display selection
—
161
Speed setting/key lock operation selection 0, 1, 10, 11
—
168
Parameter for manufacturer setting. Do not set.
—
169
170
Watt-hour meter clear
171
Operation hour meter clear
Name
0, 5, 8 to 12, 14, 19, 20, 23 to 31,
36, 37, 52 to 55, 61, 62, 100
1 to 3, 5, 8 to 12, 14, 21, 24, 36,
37, 52, 53, 61, 62
0 to 4800r/min
0 to 500A
0, 1, 2, 3
0 to 5
0 to 10, 101 to 110
0.1 to 360s
0
0 to 30%
0, 1, 10, 11
0 to 8
0 to 3, 14 to 17
0, 1, 2
0, 1, 2
0, 1, 2, 3, 4, 6, 7
0 to 31 (0 to 247)
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to 10, 9999
0, 0.1 to 999.8s, 9999
0 to 150ms, 9999
0, 1, 2
0 to 4800r/min
0 to 4800r/min
0 to 4800r/min, 9999
0, 20, 21, 50, 51, 60, 61
0.1 to 1000%, 9999
0.1 to 3600s, 9999
0 to 100%, 9999
0 to 100%, 9999
0 to 100%, 9999
0.01 to 10s, 9999
2, 4, 6, 8, 10, 102, 104, 106, 108,
110
0 to 4800r/min, 9999
0 to 200%
0 to 200%
0 to 1s
0 to 31, 100, 101
0 to 25s, 9999
0, 9999
0, 10, 9999
0, 9999
Minimum
Setting Range
Setting
Increments
1
1
1r/min
0.01c
1
1
1
0.1s
1
0.1%
1
1
1
1
1
1
0.01s
0.01s
1
1
1
1
1
0.1s
1
1
1r/min
1r/min
1r/min
1
0.1%
0.1s
0.1%
0.1%
0.01%
0.01s
1
1r/min
0.1%
0.1s
0.1%
0.01s
1
0.1s
1
1
1
1
Initial
Customer
Value
Setting
0
1
3000r/min
Rated
motor
current
0
0
0
1s
0
0%
1
1
14
0
0
0
5s
5s
0
192
1
2
1
0
9999
1
3000r/min
3000r/min
9999
0
100%
1s
9999
9999
9999
9999
110
9999
150%
0s
5%
0.5s
0
0s
0
0
9999
9999
28