Mitsubishi Electric FR-E700EX Manual page 7

Sensorless servo
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Operating
Operation
panel
status
Parameter
unit
Fault record
(FR-PU07)
Interactive
guidance
Protective
functions
Protective/
warning function
Warning
functions
Surrounding air temperature
Ambient humidity
Storage temperature
Atmosphere
Altitude/vibration

During the load fluctuation of 0 to 100%

This operation guide is only available with option parameter unit (FR-PU07).

This protective function does not function in the initial status.

When using the drive units at the surrounding air temperature of 40°C or less, the drive units can be installed closely attached (0cm clearance).

Temperatures applicable for a short time, e.g. in transit.
9
The following operating status can be displayed: rotation speed (output frequency), output current
(steady), output voltage, speed setting value (frequency setting value), converter output voltage,
regenerative brake duty, electronic thermal relay function load factor, output current peak value,
converter output voltage peak value, output power, position pulse, cumulative energization time,
actual operation time, motor load factor (torque monitor), position command, ideal speed command,
speed command, cumulative power, PID set point, PID measured value, PID deviation, drive unit I/O
terminal monitor, motor thermal load factor, and drive unit thermal load factor.
Fault record is displayed when a fault occurs. Past 8 fault records (output voltage/current/frequency/
cumulative energization time right before the fault occurs) are stored.
Function (help) for operation guide
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration,
overvoltage during acceleration, overvoltage during constant speed, overvoltage during
deceleration, drive unit protection thermal operation, motor protection thermal operation, heatsink
overheat, input phase failure
at start
, output phase failure, external thermal relay operation

PU disconnection, retry count excess
overheat, analog input error, USB communication error, loss of synchronism detection, overspeed
occurrence, speed deviation excess detection, excessive position fault, acceleration rate error,
internal board fault, internal circuit fault
Overcurrent torque limit, overvoltage stall prevention, PU stop, parameter write error, regenerative
brake prealarm
, electronic thermal relay function prealarm, maintenance output

home position return setting error
password locked
, drive unit reset

-10°C to +50°C (non-freezing)
90%RH or less (non-condensing)
-20°C to +65°C

Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Maximum 1000m above sea level, 5.9m/s

, stop by the torque limit, output side earth (ground) fault overcurrent

, CPU fault, brake transistor alarm, inrush resistance

, home position return uncompleted, operation panel lock,


2
or less at 10 to 55Hz (directions of X, Y, Z axes)
, option fault
, parameter error,


, undervoltage,
