Toro 34230 Operator's Manual page 77

Stand-on e-spreader/sprayer
Table of Contents

Advertisement

Sprayer Fault Code Table (cont'd.)
Motor Overcurrent !02
The motor overcurrent fault code !02 displays if the motor load
circuit draws too much current.
Check the motor and inspect it for damage and wear.
Fault code !02 displays in the sprayer and information display.
The LED status light illuminates red.
Check that pin 6 (M
O
OTOR
seated and locked in the controller connector.
Motor Wire !05
The motor wire fault code !05 displays if the sprayer controller
cannot sense the load circuits (O
sprayer and information display and the motor.
Fault code !05 displays in the sprayer and information display.
The LED status light illuminates red.
Motor Open !06
The motor open fault code !06 displays if the sprayer controller
cannot sense the motor signal circuit (M
Fault code !06 displays in the sprayer and information display.
The LED status light illuminates red.
1) and pin 8 (M
O
UT
OTOR
UT
1 or O
2) between the
UT
UT
I
).
OTOR
N
2) are
1. Fault code !02 (motor overcurrent)
77
1. Fault code !05 (motor wire)
1. Fault code !06 (motor open)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents