Cleaning the Strainer
Service Interval: After each use
Important:
If you used wettable-powder
chemicals, clean the strainer after each time that
you rinse the sprayer tank.
1.
Empty the sprayer tank; refer to
Sprayer Tank (page
2.
Rotate the handle of the pump-shutoff valve 90°
counterclockwise to the
64).
Figure 64
1. Strainer
3.
Align a drain pan under the strainer
4.
Rotate the strainer bowl counterclockwise and
remove the bowl and screen from the body of
the strainer
(Figure
Note:
Remove the strainer bowl by hand.
Note:
Replace the gasket or screen or both if
these parts are worn or damaged.
Emptying the
45).
position
(Figure
CLOSE
2. Pump-shutoff valve
(Figure
65).
g249175
1. Strainer body
2. Gasket
5.
Allow any residual chemical solution to drain
64).
from the strainer body.
Note:
Dispose of the waste solution according
to local codes and the chemical manufacturer's
instructions.
6.
Use a soft-bristle brush and clean water to clean
the screen and bowl.
7.
Install the screen into the strainer body
65).
8.
Install the gasket and strainer bowl onto the
strainer body, and hand tighten the bowl
65).
9.
Rotate the handle of the pump-shutoff valve 90°
clockwise to the
52
Figure 65
3. Screen
4. Strainer bowl
position
(Figure
64).
OPEN
g027402