P1 - Black
Hot/Power
P2 - Green
Ground/Earth
P-3 - Red
Hot/Power
Ferrite Core

Figure 8. Hard wire VersiCharge

11. Replace barrier and secure with the two screws
which were removed in the beginning.
12. Replace hinged cover, securing with four Phillips
head screws. Swing the unit closed until the bracket clip
engages and secure the charger with the tamper-resistant
security screws.
13. Turn the circuit breaker for this circuit to the 'ON'
position.

3.2 Amperage Adjustment

DANGER Hazardous voltage. Will cause death,
serious injury. Turn off power before working on
this equipment.
Installation and Operations Manual

Figure 9. Amperage dial setting

The VersiCharge has the option to set the maximum amperage/
power that the car may draw using the Amperage Adjustment
dial.
NOTE: The VersiCharge cannot control the power draw
to the EV, it can only communicate the current
capacity to the VersiCharge to the EV.

3.2.1 Dial Settings

NOTE: The Amperage Adjustment dial is for use by a
qualified technician/electrician only.
• When changing the Amperage Adjustment dial,
verify that the VersiCharge is disconnected from
power.
Amperage Settings
Switch Position
0
1
2
3
4
5
Settings: 0 - 4 amperage adjustment settings are used for
the 40 amp charger (note: the #5 position will cause a bad
switch fault for the 40 amp charger) and 0 - 5 amperage
adjustment settings are used for the 48 amp charger. Setting
the amperage adjustment higher than 5 will result in a fault.
| VersiCharge™ AC
Amperage
12
16
24
32
40
48
13