• Do not use this product if the enclosure or the EV connector
is broken, cracked, open, or shows any other indication of
damage.
• A torque driver shall be used to make power connections to
ensure that adequate contact pressure is applied. See the
installation section of this manual for additional details.
• A VersiCharge charging station includes wire connector
instructions for field installed wiring. Special instructions
included in this manual must be followed to ensure proper
installation.
• When a VersiCharge is hardwired during installation, power
connections shall be made at line terminals with 14.5 in-lb.
torque driver.
• An insulated grounding conductor that is identical in size,
insulation material, and thickness to the grounded and
ungrounded branch-circuit supply conductors, except that it
is green with or without one or more yellow stripes, shall be
installed as part of the branch circuit that supplies the
VersiCharge or system.
• The grounding conductor shall be grounded to earth at the
service equipment or, when supplied by a separately derived
system, at the supply transformer.
• Do not attempt to operate this VersiCharge, if the ambient
temperature is greater than 50°C(122°F)
• #6 75C copper wire should be used for 48 A charger and
#8 75C copper wire should be used for a 40A charger. NOTE:
1. Wire must have a temperature rating of 75C or higher). 2.
Do not set the amp switch higher than 40A unless hardwired
to a dedicated 60A branch protection circuit breaker.
• CAUTION: To reduce the risk of fire, connect only to a circuit
provided with 50/60 amperes maximum branch circuit
overcurrent protection in accordance with the ANSI/NFPA 70
National Electrical Code™.

1.5 Code and Standard References

• This VersiCharge has been designated to meet the requirements
in section 626 of the National Electric Code (NEC®).
• UL Listing with Listing Number – Siemens VersiCharge
devices are listed in UL file # E348556.
• Complies with the following UL Standards: UL 1998, UL 991,
UL2594/CSA C22.2 No.280/NMX-J-677-ANCE, UL 2231-1/CSA
C22.2 No.281.1/NMX-J-668-1, UL 2231-2/CSA C22.2
No.281.2/NMX-J-668/2-ANCE, UL 2251/CSA C22.2 No.282/
NMX-J-678-ANCE.
• EV interface compliant to SAE J-1772 Level II.
• This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a particular
Installation and Operations Manual
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the
following measures:
v Reorient or relocate the receiving antenna.
v Increase the separation between the equipment and
receiver.
v Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
v Consult the dealer or an experienced radio/TV technician
for help.
• Personal Protection Equipment: Use of proper personal
protection equipment, including, but not limited to, eye
protection, shock protection, gloves, and other appropriate
protection, is recommended when installing or servicing any
electrical equipment.
• Charging Circuit Interrupting Device (CCID): The Siemens
VersiCharge line of EV Charging Systems includes a Charging
Circuit Interrupting Device (CCID). The CCID is required by UL
Standard 2231 and is designed to detect ground faults within
the system and disconnect power from the downstream
conductors, when a fault is detected.
DANGER Explosion hazard. This equipment has
arcing or sparking parts that should not be
exposed to flammable vapors. This equipment
should be installed at least 18 inches above
floor or ground level. Use extreme caution and
follow instructions carefully.
• Arcing component in contactor: Siemens VersiCharge EV
Charging Systems include a contactor that, when opened
or closed, will cause a short duration arc. The contactor is
enclosed in an appropriate electrical enclosure, but if an arc
occurs in the presence of flammable vapors, the vapors
could ignite, creating an explosion. Store flammable vapors
away from all electrical equipment and, should vapors be
present, allow sufficient time for ventilation before
operating this equipment.

1.6 Product Labels

The following symbols appear on the product label and are
described here:
This label indicates the risk of hazardous voltage and electric
shock which will cause death, serious injury, or substantial
damage. Turn off power supplying this VersiCharge before
working inside.
| VersiCharge™ AC
7