ISSUE
The water conditioner
fails to regenerate.
Loss of water pressure.
Loss of mineral through
drain line.
Iron in conditioned
water.
Control cycles
continuously.
The drain flows
continuously.
Page 9
www.123filter.com

Troubleshooting

POSSIBLE CAUSE
Electrical service to the unit has
been interrupted.
The timer is defective.
Power failure.
Iron buildup in line to water
conditioner.
Iron buildup in water conditioner.
Inlet of control plugged due to
foreign material is broken loose
from pipes by recent work done on
the plumbing system.
The air in the water system.
Improperly sized drain line flow
control.
Fouled mineral bed.
Misadjusted, broken, or shorted
switch.
The valve is not programming
correctly.
Foreign material in control.
Internal control leak.
| (678) 261-7611 |
POSSIBLE SOLUTION
Assure permanent electrical
service (check fuse, plug, pull
chain, or switch).
Replace timer.
Reset time of day.
Clean line to water conditioner.
Clean control and add the
mineral cleaner to the mineral
bed. Increase frequency of
regeneration.
Remove piston and clean control.
Assure that the well system has
proper air eliminator control.
Check for the dry well condition.
Check for proper drain rate.
Check backwash. Increase
frequency of regeneration.
Increase backwash time.
Determine if the switch or timer
is faulty and replace it, or replace
the complete power head.
Check timer program and
positioning of control. Replace
power head assembly if not
positioning correctly.
Remove power head assembly
and inspect bore. Remove
foreign material and check
control in various regeneration
positions.
Replace seals and piston
assembly.