Sensor Design - Siemens SITRANS F Series Operating Instructions Manual

Coriolis flowmeters
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

11.4

Sensor design

Description
Dimension and weight
Process connectors
Electrical connection
Material
Measuring tube design
Self-draining design
SITRANS FC310
Operating Instructions, 01/2019, A5E44036384-AB
Measuring tubes
Process connectors
Sensor enclosure
DSL enclosure
Specification
See "Sensor dimensions" (Page 121)
● EN1092-1 B1 PN16, PN40
● EN1092-1 B2 PN63, PN100
● EN1092-1 D (gasket groove), PN40
● ASME B16.5 RF, Cl 150, Cl 300, Cl 600, Cl 900, CI1500
● ISO 228-1 G *
● ASME B1.20.1 NPT *
● DIN 11851 Hyg. Screw **
● DIN 32676 (ISO) Clamp Row B *
● SMS1145 - Hyg. Screwed
● JIS B 2220, 10K, 20K
● EN 1092-1 PN 16, PN40, NAMUR length
● M12 connector with 4-wire cable
● Standard cable with polymer / brass / stainless steel cable
glands (metric or NPT)
● Armored cable with stainless steel armored cable glands
(metric or NPT)
● Conduit entries (metric or NPT)
● AISI 316L / EN1.4404
● C4 (2.4610) nickel alloy or C22 (2.4602) nickel alloy
● Standard:
AISI 316L / EN1.4435 or EN1.4404
C4 (2.4610) nickel alloy or C22 (2.4602) nickel alloy
Stainless steel 1.4404 (AISI 316L), 1.4301 (AISI 304), 1.4308
(ASTM CF8)
Aluminum with corrosion-resistant coating
Split flow through 2 parallel tubes with combined cross-section
area 50% of the nominal pipe
The measuring tubes are bent in a trapezoidal curve
Yes, when mounted vertically
Technical data
11.4 Sensor design
109