NetVanta 6360 Hardware Installation Guide

DSL Features

Variable rate bonding for the SHDSL loops
Automatic failover and recovery
Plug-and-play automatic line detection
ITU-G.991.2-2003, SHDSL Annex B

Ethernet Features

IEEE 802.1p priority marking
IEEE 802.1d dynamic/transparent bridging
IEEE 802.1Q virtual local area network (VLAN) tagging
IEEE 802.3u Ethernet
MEF 9/14 certified EPL, EVPL
Ethernet Services Support
Priority queuing of traffic based on VLAN priority
Supports eight class of service (CoS) queues
Per UNI port, CE VLAN ID (C-Tag) and/or CE VLAN P-bits, DSCP fields
Single stack VLAN and double stack VLANs (Q-in-Q)
Manipulation based on 802.1p and DSCP fields
STAG TPID provisioning supports 802.1ad and802.1Q standards
Port-based service support
Services Scale and Flexibility
Configurable EtherType and TPID for service flexibility
VLAN IDs 2 to 4090; EVC configurable in the range of 1 to 4090
Ingress policers (tr3CM), CIR and EIR settings to 64 kbps granularity, configurable burst through
EBS, CBS settings
Egress shaping per port

Fault and Performance Management

IEEE 802.3ah EFM standard
ITU-T Y.1731 CFM, PM
Supports OAM management status and loopback messaging

Environment

Operating Temperature: 0°C to 50°C (32°F to 122°F)
Storage Temperature: -20°C to 70°C (-4°F to 158°F)
Relative Humidity: Up to 95 percent, noncondensing

Physical and Power

Chassis: 1U high, 19-inch or 23-inch rack mountable metal enclosure
Dimensions: 1.72-inch H x 17.22-inch W x 13.4-inch D
Power: 110 to 240 VAC, 50/60 Hz
Power: 48 VDC
617006364F1-34A
Copyright © 2014 ADTRAN, Inc.
Features and Specifications