NetVanta 4660 Chassis
NetVanta 4660 Chassis (2nd Generation)
NetVanta 5660 Chassis
NetVanta 5660 Chassis (2nd Generation)
NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex A
NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex B
NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex A
NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex B
NetVanta Carrier Ethernet Quad VDSL2 EFM Module, Annex A
NetVanta Carrier Ethernet Quad VDSL2 EFM Module, Annex B

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN 17004660F1/F3

  • Page 1 NetVanta 4660/5660 Hardware Installation Guide 17004660F1/F3 NetVanta 4660 Chassis 17024660F1 NetVanta 4660 Chassis (2nd Generation) 17005660F1 NetVanta 5660 Chassis 17025660F1 NetVanta 5660 Chassis (2nd Generation) 17406368F1 NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex A 17406368F3 NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex B...
  • Page 2 To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.
  • Page 3 NetVanta 4660/5660 Series Conventions Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption or damage to the equipment. Warnings provide information that could prevent injury or endangerment to human life. 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 4 These units contain no user-serviceable parts. They should only be serviced by qualified service personnel. Additional safety guidelines, such as Waste Electrical and Electronic Equipment (WEEE), are given in the document NetVanta Safety and Regulatory Information available online at http://supportforums.adtran.com. Save These Important Safety Instructions Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 5 Advance notification and the opportunity to maintain uninterrupted service are given. 4. If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty information. The telephone company may require this equipment to be disconnected from the network until the problem is corrected, or it is certain the equipment is not malfunctioning.
  • Page 6 ICES-003 of the Department of Communications. Cet appareil numérique respecte les limites de bruits radioelectriques applicables aux appareils numériques de Class A prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques,” NMB-003 edictee par le ministre des Communications. Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 7 GNU General Public License (GPL). For a list of third-party software and their licenses, go to  http://www.adtran.com/software/EULA. You can obtain the complete corresponding source code of such software components from ADTRAN for a period of three years after our last shipment of this product by sending a money order or check for $5 to: ADTRAN, Inc, P.O.
  • Page 8: Table Of Contents

    Network Module Pinouts ............33 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 9 Network Module Installation ..........30 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 10 Table A-8. Quad VDSL2 Pinouts ............34 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 11: Introduction

    For information on NetVanta 4660/5660 Series configuration for a specific application, refer to the configuration guides provided on the ADTRAN Support Community. For details on the command line interface (CLI), refer to the AOS Command Reference Guide. All other related documents are also available online at http://supportforums.adtran.com. 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 12: Physical Description

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
  • Page 13: Netvanta 4660/5660 Series Front Panel Design

    CONSOLE Connection directly to an external modem requires a cross-over cable. 10/100/1000Base-T Ethernet Interfaces port consists of one SFP slot for connectivity over fiber. The status LED is GIG 0/1 located above the interface. 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 14: Led Descriptions

    Only one fan is functioning. Red (solid) Neither fan is functioning. GIG 0/1 through  Port is inactive or administratively disabled. GIG 0/5 Green (solid) The link is up. Amber (flashing) There is activity on the link. Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 15: Features And Specifications

    • Open Shortest Path First (OSPF) • RIP (v1 and v2) • • IGMP v2 • Layer 3 Backup • Multi-VRF CE • • PPPoE • PAP and CHAP • Multihoming • VRRP 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 16: Security

    • RADIUS AAA • SSH CLI and SSL GUI Content Filtering • Inherent URL filter • Top website reports • Integration with Websense® Virtual Private Network (VPN) (Optional) • IPSec Tunnel Mode: Tunnels 1,000 Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 17: Dsl Features

    Fault and Performance Management • IEEE 802.3ah EFM standard • ITU-T Y.1731 CFM, PM • IEEE 802.3ah Link OAM • ITU-T Y.1731 CFM, PM • Supports OAM management status and loopback messaging • Network monitoring enhancements 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 18: Environment

    FCC Part 15, Class B • UL 60950-1, Second Edition • EN 60950, Second Edition, A1, A11, A12 • AS/NZS 60950.1 • CSA C22.2 No. 60950-1, Second Edition • CE Mark • ETSI 300 • RoHS Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 19: Option Modules

    25 This section describes each module, providing individual card specifications and features. Refer to Appendix A on page 31 for pinout information. Installing Network Modules on page 29 provides information on card installation. 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 20: Network Modules

    SHDSL loop is trained and EFM group is established. Amber (flashing) SHDSL loop is trained but EFM group is not established. Amber (solid) SHDSL loop is in test. Red (flashing) SHDSL loop is in handshake process. Red (solid) SHDSL loop connection failure. Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 21: Figure 3. Netvanta Carrier Ethernet Quad Shdsl Efm Module, Annex B

    SHDSL loop is trained and EFM group is established. Amber (flashing) SHDSL loop is trained but EFM group is not established. Amber (solid) SHDSL loop is in test. Red (flashing) SHDSL loop is in handshake process. Red (solid) SHDSL loop connection failure. 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 22: Figure 4. Netvanta Octal Shdsl Efm Network Module, Annex A

    SHDSL loop is trained and EFM group is established. Amber (flashing) SHDSL loop is trained but EFM group is not established. Amber (solid) SHDSL loop is in test. Red (flashing) SHDSL loop is in handshake process. Red (solid) SHDSL loop connection failure. Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 23: Figure 5. Netvanta Carrier Ethernet Octal Shdsl Efm Module, Annex B

    SHDSL loop is trained and EFM group is established. Amber (flashing) SHDSL loop is trained but EFM group is not established. Amber (solid) SHDSL loop is in test. Red (flashing) SHDSL loop is in handshake process. Red (solid) SHDSL loop connection failure. 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 24: Figure 6. Netvanta Carrier Ethernet Quad Vdsl2 Efm Module, Annex A

    VDSL loop is trained and EFM group is established. Amber (flashing) VDSL loop is trained but EFM group is not established. Amber (solid) VDSL loop is in test. Red (flashing) VDSL loop is in handshake process. Red (solid) VDSL loop connection failure. Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 25: Figure 7. Netvanta Carrier Ethernet Quad Vdsl2 Efm Module, Annex B

    VDSL loop is trained and EFM group is established. Amber (flashing) VDSL loop is trained but EFM group is not established. Amber (solid) VDSL loop is in test. Red (flashing) VDSL loop is in handshake process. Red (solid) VDSL loop connection failure. 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 26: Unit Installation

    • Ethernet cables are intended for intrabuilding use only. Connecting an ADTRAN unit directly to Ethernet cables that run outside the building in which the unit is housed will void the user's warranty and could create a fire or shock hazard.
  • Page 27: Mounting Options

    Have an assistant hold the unit in position as you install two mounting bolts through the unit’s brackets and into the equipment rack using a #2 Phillips-head screwdriver. Apply power to the unit (refer to Supplying Power to the Unit on page 29). 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 28: Figure 8. Wallmount Installation

    (see Figure 8 on page 28). Proceed to the steps given in Connecting Ground to the Unit on page 29 Supplying Power to the Unit on page Figure 8. Wallmount Installation Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 29: Connecting Ground To The Unit

    The network modules are installed into the front panel option module slot. The following table lists the installation steps. Also, see Figure 9 on page For NetVanta modules with outside plant connections, ensure that all cables are removed from the module before installing or removing it from the NetVanta chassis. 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 30: Figure 9. Network Module Installation

    ADTRAN’s Support Forum For details on the CLI, refer to the AOS Command Reference Guide. All other related documents are also available online on ADTRAN’s Support Forum. Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 31: Appendix A. Connector Pin Definitions

    Clear to Send (output) — Unused Table A-2. SFP Slot Pinouts Name Name TGND RGND TX FAULT TX DISABLE MOD DEF(2) RGND MOD DEF(1) VccR MOD DEF(0) VccT RATE SELECT TGND RGND RGND TGND 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 32: Table A-3. 1000Base-T Gigabit Ethernet Port Pinouts

    Transmit/Receive Negative TRD1- Transmit/Receive Negative TRD3+ Transmit/Receive Positive TRD3- Transmit/Receive Negative Table A-4. T4 Port Pinouts Name Description — Unused Transmit data toward the network–Ring Transmit data toward the network–Tip — Unused Ground — Unused Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...
  • Page 33: Network Module Pinouts

    Loop 8 - Tip Loop 6 - Ring Loop 8 - Ring — Unused — Unused Loop 5 - Tip Loop 7 - Tip Loop 5 - Ring Loop 7 - Ring — Unused — Unused 617004660F1-34B Copyright © 2019 ADTRAN, Inc.
  • Page 34: Table A-8. Quad Vdsl2 Pinouts

    Appendix A NetVanta 4660/5660 Series Table A-8. Quad VDSL2 Pinouts Name Description 1, 2 — Unused Ring Ring lead of the 2-wire interface Tip lead of the 2-wire interface 5, 6 — Unused Copyright © 2019 ADTRAN, Inc. 617004660F1-34B...