Position Of Ld4 Rj Card; Connecting Base Stations - Aastra NeXspan C Installation Manual

Integrated dect service
Table of Contents

Advertisement

SW7 and SW8: the jumpers allow the selection of a 40 V or 48 V power supply.
Note: The power supply units of the NeXspan range do not supply ISDN 40 V. To supply 40 V
to sets and/or base stations, connect an external power supply unit to the T3 connector
on the LD4 RJ card.
Table 9: Description of switches SW7 and SW8 on the LD4 RJ card

4.4.3 Position of LD4 RJ card

The possible slots and restrictions for the LD4 card in a NeXspan cabinet are the same as for the
LD4NX card (see section 4.6.5).

4.4.4 Connecting base stations

Each base station is connected to the ISDN S0 (BRI) of an LD4 RJ card, and uses two pairs: 1
transmit pair and 1 receive pair.
Note: If there are a DECT base station and an S0 terminal (other than the base station) on the
same card, the base station must be powered with 40V. The NeXspan power supply
units do not supply ISDN 40 V. To supply 40 V to sets and/or base stations, connect an
external power supply unit to the T3 connector on the LD4 RJ card.
Page 76
SW7 and SW8
Positions
40
3
3
2
2
1
1
48
40
3
3
2
2
1
1
48
CONSOLE
1-2
48 V selected
2-3
40 V selected
T
3
S
3
01/2007
Feature
T
0
S
0
LD4 X
AMT/PTD/PBX/0020/2/4/EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexspan sNexspan lNexspan dNexspan 50Nexspan 500

Table of Contents