Daikin EWAA0 DAV3P Series Installer's Reference Manual page 230

Packaged air-cooled water chillers and packaged air to water heat pumps
Table of Contents

Advertisement

4/10
Field settings table
Breadcrumb Field code
Setting name
9.1
[4-0A]
Configuration
9.1
[6-03]
Capacity step 1
9.1
[6-04]
Additional capacity step 2
└─ Main zone
9.1
[2-0C]
Emitter type
9.1
[C-07]
Control
9.1
Setpoint mode
9.1
Schedule
9.1
[1-00]
Low ambient temp. for LWT main zone heating WD curve.
9.1
[1-01]
High ambient temp. for LWT main zone heating WD curve.
9.1
[1-02]
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
9.1
[1-03]
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
9.1
[1-06]
Low ambient temp. for LWT main zone cooling WD curve.
9.1
[1-07]
High ambient temp. for LWT main zone cooling WD curve.
9.1
[1-08]
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
9.1
[1-09]
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
└─ Additional zone
9.1
[2-0D]
Emitter type
9.1
Setpoint mode
9.1
Schedule
9.1
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
9.1
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
9.1
[0-02]
High ambient temp. for LWT add zone heating WD curve.
9.1
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
9.1
[0-04]
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
9.1
[0-05]
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
9.1
[0-06]
High ambient temp. for LWT add zone cooling WD curve.
9.1
[0-07]
Low ambient temp. for LWT add zone cooling WD curve.
└─ Tank
9.1
[6-0D]
Heat up mode
9.1
[6-0A]
Comfort setpoint
9.1
[6-0B]
Eco setpoint
Reheat setpoint
9.1
[6-0C]
└─ Domestic hot water
9.2.1
[E-05]
Domestic hot water
[E-06]
[E-07]
9.2.2
[D-02]
DHW pump
9.2.4
[D-07]
Solar
└─ Back up heater
9.3.1
[E-03]
BUH type
9.3.2
[5-0D]
Voltage
9.3.3
[4-0A]
Configuration
9.3.4
[6-03]
Capacity step 1
9.3.5
[6-04]
Additional capacity step 2
9.3.6
[5-00]
Equilibrium
9.3.7
[5-01]
Equilibrium temperature
9.3.8
[4-00]
Operation
4P627274-1 - 2020.09
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0: 1
1: 1/1+2
2: 1/2
3: 1/2 + 1/1+2 in emergency
0~10kW, step: 0,2kW
0kW
0~10kW, step: 0,2kW
0kW
0: Underfloor heating
1: Fancoil unit
2: Radiator
0: LWT control
1: Ext RT control
2: RT control
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
0: No
1: Yes
-40~5°C, step: 1°C
-10°C
10~25°C, step: 1°C
15°C
[9-01]~[9-00], step: 1°C
35°C
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
10~25°C, step: 1°C
20°C
25~43°C, step: 1°C
35°C
[9-03]~[9-02]°C, step: 1°C
22°C
[9-03]~[9-02]°C, step: 1°C
18°C
0: Underfloor heating
1: Fancoil unit
2: Radiator
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
0: No
1: Yes
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
[9-05]~[9-06]°C, step: 1°C
55°C
10~25°C, step: 1°C
15°C
-40~5°C, step: 1°C
-10°C
[9-07]~[9-08]°C, step: 1°C
18°C
[9-07]~[9-08]°C, step: 1°C
22°C
25~43°C, step: 1°C
35°C
10~25°C, step: 1°C
20°C
0: Reheat only
1: Reheat + sched.
2: Scheduled only
30~[6-0E]°C, step: 1°C
50°C
30~min(50, [6-0E])°C, step: 1°C
45°C
30~min(50, [6-0E])°C, step: 1°C
45°C
0: No DHW
2: EKHW
7: EKHWP
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circulation Pump
4: Circulation Pump and disinf. Shunt
0: No
1: Yes
0: no BUH
1: External BUH
0: 230V, 1~
1: 230V, 3~
2: 400V, 3~
0: 1
1: 1/1+2
2: 1/2
3: 1/2 + 1/1+2 in emergency
0~10kW, step: 0,2kW
0kW
0~10kW, step: 0,2kW
0kW
0: Allowed
1: Not allowed
-15~35°C, step: 1°C
0°C
0: Disabled
1: Enabled
2: Only DHW
Installer setting at variance with
default value
Date
Value
(*1) EWAA*
(*2) EWYA*