Testing The Installation - Husqvarna Automower Solar Hybrid Technical Manual

Hide thumbs Also See for Automower Solar Hybrid:
Table of Contents

Advertisement

If the guide wire runs on the left, seen in the
mower's direction of entry, the guide wire must
be routed at least 2 m (6.5 ft) from the front edge
of the charging plate. In this instance,
Automower will find it difficult to find the low loop
signal strengths, i.e. if a high Corridor width
value is used. There is then a risk that the mower
will not find the right strength on the loop signal
and can not follow the guide wire.
If the guide wire is to be used for the Follow loop in
function:
When the guide wire is only used for the Follow
loop in function it is sufficient for the guide wire to
be routed 70 cm (2.5 ft) straight out from the front
edge of the plate.
Should the mower, when it follows the guide
wire, collide with an obstacle, it changes direction
and leaves the guide wire.
The standard boundary wire, 501 98 03-01, should be
used for the guide wire.
The guide wire should be connected to the boundary
wire with the help of an original connector,
501 98 02-01. See the picture opposite.

3.4 Testing the installation

This section only applies to 220 AC, 230 ACX and
Solar Hybrid.
3.4.1 Test IN (3-2-4)
The Test IN (3-2-4) function is used to test how
Automower finds its way into the charging station.
Find the maximum Corridor width through trial and
error:
1.
Position the mower where you want to make the
test and direct it towards the wire, if possible at a
distance of a few metres.
2.
Select Corridor width (guide 1, guide 2 and
boundary).
3.
Select the function Test IN (3-2-4).When the
function is selected the mower will immediately
follow the boundary wire or the guide wire,
depending on which one it finds first, in to the
charging station.
4.
Check that the mower finds the charging station
without problem. If there is a passage and the
mower can not run through it, the Corridor width
value is set too high.
3. INSTALLATION
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT
2 m (6.5 ft)
3-2-4
3012-710
3012-643
English - 49