Supply voltage
Motor protection
Enclosure class
Insulation class
Relative air humidity
System pressure
Inlet pressure
EMC
Sound pressure level
Ambient temperature
Temperature class
Surface temperature
Liquid temperature
Contents:
.
1 x 230 V – 10 %/+ 6 %, 50 Hz, PE
The pump requires no external motor protection.
IP 42
F
Maximum 95 %
Maximum 1.0 MPa, 10 bar, 102 m head
≤ +75 °C
+90 °C
+110 °C
EN 61000-6-2 and EN 61000-6-3
The sound pressure level of the pump is lower than 43 dB(A).
0 °C to +40 °C
TF110 to CEN 335-2-51
The maximum surface temperature will not exceed +125 °C.
+2 °C to +110 °C
To avoid condensation in the control box and stator, the liquid temperature
must always be higher than the ambient temperature.
0
10
20
30
35
40
0.05 bar, 0.005 MPa, 0.5 m head
0.28 bar, 0.028 MPa, 2.8 m head
1.08 bar, 0.108 MPa, 10.8 m head
2
10
20
30
35
40
23
110
110
110
110
90
70