17.2.2
Operation mode during Heating Only Operation
The table below shows the operation mode comparison when Heating Only Operation Mode Activated and
Deactivated.
Operation
Mode
After 30s sampling, regardless of the indoor intake or
AUTO
outdoor intake temperature judgment, the unit will run
Heating operation.
HEAT
The unit will run Heating operation.
COOL
The unit will stop and Power LED blinking.
DRY
The unit will stop and Power LED blinking.
NANOE
The unit will stop and Power LED blinking.
Stand-alone
The unit will run Force Cooling Operation for
Force Cooling
X_CTRYTM [15] minutes
Force Heating
The unit will run Force Heating operation.
The unit will turn ON by the timer and run Auto
AUTO
Operation. After 30s sampling, regardless of the indoor
(with Timer)
intake or outdoor intake temperature judgment, the unit
will run Heating operation.
HEAT
The unit will turn ON by the timer and run Heating
(with Timer)
Operation.
COOL
The unit will not turn ON by the timer. Power LED
(with Timer)
blinking.
DRY
The unit will not turn ON by the timer. Power LED
(with Timer)
blinking.
Cooling
The unit will stop and Power LED blinking.
Test Mode
Heating
The unit will operate according to specify Heating test
Test Mode
mode operation parameter.
Heating Only Operation Mode Activated
Heating Only Operation Mode Deactivated
After 30s sampling, the unit will judge the operation
mode base on remote controller temperature setting and
Indoor Intake Sensor (New Auto Mode) or Outdoor
Intake Sensor (Old Auto Mode).
The unit will run Heating operation.
The unit will run Cooling operation.
The unit will run Cooling Dry operation.
The unit will run Nanoe Stand-alone operation.
The unit will run Force Cooling operation.
The unit will run Force Heating operation.
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, the unit will judge the
operation mode base on remote controller temperature
setting and Indoor Intake Sensor (New Auto Mode) or
Outdoor Intake Sensor (Old Auto Mode).
The unit will turn ON by the timer and run Heating
Operation.
The unit will turn ON by the timer and run Cooling
Operation.
The unit will turn ON by the timer and run Cooling Dry
Operation.
The unit will operate according to specify Cooling test
mode operation parameter.
The unit will operate according to specify Heating test
mode operation parameter.
103

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents