Advertisement

Quick Links

DCS 300
INSTALLATION
AND
SERVICE MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Raven DCS 300

  • Page 1 DCS 300 INSTALLATION SERVICE MANUAL...
  • Page 2 N O T I C E The use of the suspension type fertilizers and lime slurries will significantly reduce the life of the plastic parts in the Flow Meter and motorized Control Valve. Check the rotor and inlet hub assembly in the Flow Meter frequently for worn parts. Excessive wear can affect accuracy.
  • Page 4 Manual Rev. C, DCS 300, 10-97 Order: 50, 10-28-97, #016-0159-577...
  • Page 5: Table Of Contents

    016-0159-577 TABLE OF CONTENTS 10/97 SYMBOL DEFINITION .............................. 2 INTRODUCTION ............................... 3 INSTALLATION ................................. 4 1. MOUNTING THE ENCODER ..........4 2. MOUNTING THE FLOW METER ........... 5 3. MOUNTING THE CONTROL VALVE ........6 4. MOUNTING THE CONSOLE AND CABLING ........6 BATTERY CONNECTIONS ............................
  • Page 6: Symbol Definition

    SYMBOL DEFINITION - Gallons - pounds - Liters - kilograms - Gallons per ton - Miles per hour lit/MT - Liters per metric ton - Kilometers - Pounds per square inch km/h - Kilometers per hour - Kilopascal - Volume in gallons lb/mile - Pounds per mile - Volume in liters...
  • Page 7: Introduction

    INTRODUCTION The Raven DCS 300 (DE-ICE CONTROL SYSTEM) is designed to improve the uniformity of pre- wetting applications automatically. Its performance relies on the installation and preventive maintenance of the complete system. It is important that this Installation and Service Manual be reviewed thoroughly before operating the system.
  • Page 8: Installation

    INSTALLATION MOUNTING THE ENCODER Mount Encoder on output shaft of conveyor or other shaft which rotates at a known ratio to the conveyor. Apply grease to Encoder shaft, conveyor shaft, and Encoder coupler (fits 1" diameter conveyor shaft). Secure coupler to Encoder and conveyor shafts with set screws provided.
  • Page 9: Mounting The Flow Meter

    MOUNTING THE FLOW METER Mount the Flow Meter in the area of the boom valve per Figure 2. All flow through the Flow Meter must go to the boom valve only, i.e. no return line to tank or pump after Flow Meter. Mount Flow Meter horizontal to the ground.
  • Page 10: Mounting The Control Valve

    MOUNTING THE CONTROL VALVE Mount the motorized Control Valve in the main hose line between the Flow Meter and the boom valve, with motor in the upright position. (For less than 3 GPM [11 lit/min], the motorized Control Valve is mounted in the by-pass line, refer to Appendix 1 for alternate plumbing diagram).
  • Page 11: Battery Connections

    BATTERY CONNECTIONS FIGURE 4 FIGURE 4 FIGURE 4 FIGURE 4 FIGURE 4...
  • Page 12: Console Features

    CONSOLE FEATURES IMPORTANT: IMPORTANT: IMPORTANT: This Console requires selection of US IMPORTANT: IMPORTANT: US US US US (gallons) or SI SI SI SI SI [liters]; and C-Sd C-Sd C-Sd (Standard Valve) or C-FC C-Sd C-Sd C-FC C-FC C-FC C-FC (Fast Close Valve). Hold DAY VOLUME key to view selections.
  • Page 13: Console Calibration

    CONSOLE CALIBRATION CALCULATING "METER CAL" The Flow Meter calibration number is stamped on the tag attached to each Flow Meter. This number is to be used for gallons [liters] per application. To convert original METER CAL from gallons to desired units of measure, see METER CAL CONVERSIONS on page 3.
  • Page 14 * Chart data from Spraying Systems Company VERIFYING FLOW RATE LIMITS: VERIFYING FLOW RATE LIMITS: VERIFYING FLOW RATE LIMITS: VERIFYING FLOW RATE LIMITS: VERIFYING FLOW RATE LIMITS: The total gallons per minute (GPM) [lit/min] flow rate of application must be within the range of that specified for the Flow Meter.
  • Page 15: Calculating "Gran Cal

    CALCULATING "GRAN CAL" Factors which can affect the product GRAN CAL numbers are the product particle size, density, temperature, and humidity. Always calibrate the material you have purchased. Complete INITIAL CONSOLE PROGRAMMING, on page 15, before proceding with this procedure. The GRAN CAL value is derived using the following procedure: Place chalk mark or tape on granular belt shaft to use as a reference point.
  • Page 16: Verifying "Gran Cal

    VERIFYING "GRAN CAL" To verify this GRAN CAL number, perform the following procedure: Use a pre-weighed box to capture granules as they are metered out. Enter the pre-determined GRAN CAL into key labelled: Enter a "0" in key labelled: Turn granular belt ON to begin collecting granules. Turn granular belt OFF when GRAN TOTAL display reads 200.
  • Page 17: Calculating "Valve Cal

    CALCULATING "VALVE CAL" The initial Control Valve calibration number for VALVE CAL is 2123 for C-Sd (standard valve), or 743 for C-F (fast valve) and C-FC (fast close valve). The VALVE CAL number is used to control response time of the Motor Control to the change in vehicle speed.
  • Page 18: Console Programming

    CONSOLE PROGRAMMING When entering data into the Console, the entry sequence is always the same. NOTE: NOTE: NOTE: Data must be entered into keys 2, 3, & 4 with the key switch turned to NOTE: NOTE: the horizontal position. Depress the key in which Depress the ENTER key.
  • Page 19: Initial Console Programming

    1. INITIAL CONSOLE PROGRAMMING When you first turn on Console power, after all installation procedures have been completed, the Console will display "US" in the display window. This means you must "calibrate" or program the Console before it can be operated. This is a one- time operation which does not have to be repeated.
  • Page 20: Other Displays

    YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE The flashing "CAL" will now extinguish. If not, repeat procedure starting at Step 5.
  • Page 21: Initial System Set-Up

    To verify maximum pressure and rate, enter 999.9 into LIQ CAL, 10 into METER CAL, 10 into GRAN CAL, and 1000 into SELF TEST. This assures that the motorized Control Valve is fully open. Verify maximum pressure and LIQ/GRAN rate. (Pressure gauge is not supplied with the DCS 300 system). NOTE: NOTE: NOTE: A pressure gauge MUST be installed to properly monitor the system.
  • Page 22: Initial System Road Test

    Verify granular and liquid volume used. PREVENTIVE MAINTENANCE Preventive maintenance is most important to assure long life of the DCS 300 system. The following maintenance procedures should be followed on a regular basis: Flush entire system with water after use of suspension type chemicals.
  • Page 23: Appendixes

    FIGURE 5 FIGURE 5 FIGURE 5 FIGURE 5 INITIAL SYSTEM SET-UP Install Polarity Reversal Jumper in motorized Control Valve Cable (Raven Part # 115-0159-415). Plumb the system as shown in Figure 5. Adjust as follows: Fill tank with water only.
  • Page 24 Verify that the boom valve operates and that no nozzles are plugged. To assure motorized Control Valve is fully closed, enter 999.9 into LIQ CAL, 10 into METER CAL, 10 into GRAN CAL, and 1000 into SELF TEST. Adjust agitator line hand valve for desired agitation. Close the main line hand valve, if necessary, to set the desired maximum operating pressure.
  • Page 25: Procedure To Test Flow Meter/Encoder Cables

    APPENDIX 2 PROCEDURE TO TEST FLOW METER/ENCODER CABLES Disconnect cable from Flow Sensor. Hold Flow Sensor cable so that the keyway is pointing in the 12 o’clock position: PIN DESIGNATIONS PIN DESIGNATIONS PIN DESIGNATIONS PIN DESIGNATIONS PIN DESIGNATIONS 2 o’clock socket location is ground. 10 o’clock socket location is power.
  • Page 26: Flow Meter Maintenance And Adjustment Procedure

    APPENDIX 3 FLOW METER MAINTENANCE AND ADJUSTMENT PROCEDURE Remove Flow Meter from sprayer and flush with clean water to remove any chemicals. NH NH NH NH WARNING: WARNING: WARNING: Thoroughly bleed nurse tank hose and all other system lines prior WARNING: WARNING: 3 3 3 3 3...
  • Page 27: Procedure To Re-Calibrate Flow Meter

    APPENDIX 4 PROCEDURE TO RE-CALIBRATE FLOW METER Enter a METER CAL number of 10 [38] in the key labelled Enter a TOTAL VOLUME of 0 in the key labelled Switch OFF all booms. Remove a boom hose and place it into a calibrated 5 gallon [19 liter] container. Switch ON appropriate boom switch (for the hose that was just placed into the 5 gallon container) and the MASTER switch.

Table of Contents