Page 2
N O T I C E The use of the suspension type fertilizers and lime slurries will significantly reduce the life of the plastic parts in the Flow Meter and motorized Control Valve. Check the rotor and inlet hub assembly in the Flow Meter frequently for worn parts. Excessive wear can affect accuracy.
016-0159-577 TABLE OF CONTENTS 10/97 SYMBOL DEFINITION .............................. 2 INTRODUCTION ............................... 3 INSTALLATION ................................. 4 1. MOUNTING THE ENCODER ..........4 2. MOUNTING THE FLOW METER ........... 5 3. MOUNTING THE CONTROL VALVE ........6 4. MOUNTING THE CONSOLE AND CABLING ........6 BATTERY CONNECTIONS ............................
SYMBOL DEFINITION - Gallons - pounds - Liters - kilograms - Gallons per ton - Miles per hour lit/MT - Liters per metric ton - Kilometers - Pounds per square inch km/h - Kilometers per hour - Kilopascal - Volume in gallons lb/mile - Pounds per mile - Volume in liters...
INTRODUCTION The Raven DCS 300 (DE-ICE CONTROL SYSTEM) is designed to improve the uniformity of pre- wetting applications automatically. Its performance relies on the installation and preventive maintenance of the complete system. It is important that this Installation and Service Manual be reviewed thoroughly before operating the system.
INSTALLATION MOUNTING THE ENCODER Mount Encoder on output shaft of conveyor or other shaft which rotates at a known ratio to the conveyor. Apply grease to Encoder shaft, conveyor shaft, and Encoder coupler (fits 1" diameter conveyor shaft). Secure coupler to Encoder and conveyor shafts with set screws provided.
MOUNTING THE FLOW METER Mount the Flow Meter in the area of the boom valve per Figure 2. All flow through the Flow Meter must go to the boom valve only, i.e. no return line to tank or pump after Flow Meter. Mount Flow Meter horizontal to the ground.
MOUNTING THE CONTROL VALVE Mount the motorized Control Valve in the main hose line between the Flow Meter and the boom valve, with motor in the upright position. (For less than 3 GPM [11 lit/min], the motorized Control Valve is mounted in the by-pass line, refer to Appendix 1 for alternate plumbing diagram).
CONSOLE FEATURES IMPORTANT: IMPORTANT: IMPORTANT: This Console requires selection of US IMPORTANT: IMPORTANT: US US US US (gallons) or SI SI SI SI SI [liters]; and C-Sd C-Sd C-Sd (Standard Valve) or C-FC C-Sd C-Sd C-FC C-FC C-FC C-FC (Fast Close Valve). Hold DAY VOLUME key to view selections.
CONSOLE CALIBRATION CALCULATING "METER CAL" The Flow Meter calibration number is stamped on the tag attached to each Flow Meter. This number is to be used for gallons [liters] per application. To convert original METER CAL from gallons to desired units of measure, see METER CAL CONVERSIONS on page 3.
Page 14
* Chart data from Spraying Systems Company VERIFYING FLOW RATE LIMITS: VERIFYING FLOW RATE LIMITS: VERIFYING FLOW RATE LIMITS: VERIFYING FLOW RATE LIMITS: VERIFYING FLOW RATE LIMITS: The total gallons per minute (GPM) [lit/min] flow rate of application must be within the range of that specified for the Flow Meter.
CALCULATING "GRAN CAL" Factors which can affect the product GRAN CAL numbers are the product particle size, density, temperature, and humidity. Always calibrate the material you have purchased. Complete INITIAL CONSOLE PROGRAMMING, on page 15, before proceding with this procedure. The GRAN CAL value is derived using the following procedure: Place chalk mark or tape on granular belt shaft to use as a reference point.
VERIFYING "GRAN CAL" To verify this GRAN CAL number, perform the following procedure: Use a pre-weighed box to capture granules as they are metered out. Enter the pre-determined GRAN CAL into key labelled: Enter a "0" in key labelled: Turn granular belt ON to begin collecting granules. Turn granular belt OFF when GRAN TOTAL display reads 200.
CALCULATING "VALVE CAL" The initial Control Valve calibration number for VALVE CAL is 2123 for C-Sd (standard valve), or 743 for C-F (fast valve) and C-FC (fast close valve). The VALVE CAL number is used to control response time of the Motor Control to the change in vehicle speed.
CONSOLE PROGRAMMING When entering data into the Console, the entry sequence is always the same. NOTE: NOTE: NOTE: Data must be entered into keys 2, 3, & 4 with the key switch turned to NOTE: NOTE: the horizontal position. Depress the key in which Depress the ENTER key.
1. INITIAL CONSOLE PROGRAMMING When you first turn on Console power, after all installation procedures have been completed, the Console will display "US" in the display window. This means you must "calibrate" or program the Console before it can be operated. This is a one- time operation which does not have to be repeated.
YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE YOU HAVE NOW COMPLETED PROGRAMMING THE CONSOLE The flashing "CAL" will now extinguish. If not, repeat procedure starting at Step 5.
To verify maximum pressure and rate, enter 999.9 into LIQ CAL, 10 into METER CAL, 10 into GRAN CAL, and 1000 into SELF TEST. This assures that the motorized Control Valve is fully open. Verify maximum pressure and LIQ/GRAN rate. (Pressure gauge is not supplied with the DCS 300 system). NOTE: NOTE: NOTE: A pressure gauge MUST be installed to properly monitor the system.
Verify granular and liquid volume used. PREVENTIVE MAINTENANCE Preventive maintenance is most important to assure long life of the DCS 300 system. The following maintenance procedures should be followed on a regular basis: Flush entire system with water after use of suspension type chemicals.
FIGURE 5 FIGURE 5 FIGURE 5 FIGURE 5 INITIAL SYSTEM SET-UP Install Polarity Reversal Jumper in motorized Control Valve Cable (Raven Part # 115-0159-415). Plumb the system as shown in Figure 5. Adjust as follows: Fill tank with water only.
Page 24
Verify that the boom valve operates and that no nozzles are plugged. To assure motorized Control Valve is fully closed, enter 999.9 into LIQ CAL, 10 into METER CAL, 10 into GRAN CAL, and 1000 into SELF TEST. Adjust agitator line hand valve for desired agitation. Close the main line hand valve, if necessary, to set the desired maximum operating pressure.
APPENDIX 2 PROCEDURE TO TEST FLOW METER/ENCODER CABLES Disconnect cable from Flow Sensor. Hold Flow Sensor cable so that the keyway is pointing in the 12 o’clock position: PIN DESIGNATIONS PIN DESIGNATIONS PIN DESIGNATIONS PIN DESIGNATIONS PIN DESIGNATIONS 2 o’clock socket location is ground. 10 o’clock socket location is power.
APPENDIX 3 FLOW METER MAINTENANCE AND ADJUSTMENT PROCEDURE Remove Flow Meter from sprayer and flush with clean water to remove any chemicals. NH NH NH NH WARNING: WARNING: WARNING: Thoroughly bleed nurse tank hose and all other system lines prior WARNING: WARNING: 3 3 3 3 3...
APPENDIX 4 PROCEDURE TO RE-CALIBRATE FLOW METER Enter a METER CAL number of 10 [38] in the key labelled Enter a TOTAL VOLUME of 0 in the key labelled Switch OFF all booms. Remove a boom hose and place it into a calibrated 5 gallon [19 liter] container. Switch ON appropriate boom switch (for the hose that was just placed into the 5 gallon container) and the MASTER switch.