Original-Betriebsanleitung
Translation of the original operating instructions
2/2 Schrägsitzventil Typ 580
2/2 Angle Seat valve Typ 580
5.6. Handling of the accessories
The seat valve can be equipped with accessories.
Optical position indicator
The optical position indicator shows the actual valve position. Thus, it can be recognized whether the valve is
open- or closed.
6.
Maintenance
Maintenance is only allowed to be carried out by trained staff.
seat valves are low-maintenance parts. They have to be checked and maintained periodically. These periods
are depending on working load and have to be defined according to valid rules.
6.1.
Wear parts
The seat seal is a wearing part and subject to natural wear.
The actuator is a low-maintenance part, if all regulations of this operation manual are respected.
Available spare parts are the actuator and the valve body.
Important Information for ordering spare parts is the article code and order number, which you will find on the
type plate of the valve.
To order spare parts, please contact us via
www.sed-flowcontrol.com
The lifetime of the valve dependent on following factors:
•
Media
•
Operating temperature
•
Operating pressure
•
Closing force
•
Correct assembly and use
6.3.
Cleaning
For external cleaning, commercially available cleaning agents can be used. Check the chemical resistance of all
materials used in the valve, which could come in contact with the cleaning agent, before applying
For sterilization processes, check if the valve is suitable for the applied process.
© 1996 - 2019 SED Flow Control GmbH
Valve closed
info@sed-flowcontrol.com
.
or asked your local dealer under
28
Valve open
BA180003; Version c vom 28.10.2019