2002 Communication Link Between Boards Broken - Zte ZXMW NR8250 Manual

Digital microwave transmission system
Table of Contents

Advertisement

ZXMW NR8250 Alarm and Notification Handling Reference
Possible Causes
The virtual interface configurations at the two ends do not match. The virtual interface
configurations include version number, area configuration, network mask, Hello timer
interval, and Dead timer interval.
Handling Procedure
Ensure that the virtual interface configurations at the two ends match.

2.3.4 2002 Communication link between boards broken

Alarm Property
l
Alarm Code: 2002
l
Alarm Information: This alarm is reported when the communication link between pe-
ripheral board and master main control board, or between slave main control board
and master main control board is interrupt.
l
Alarm Level: Critical
l
Alarm Type: Handling Alarm
Sub-code Description
None
Effect on the System
The board fails to communicate with the active main-control board, causing that the
services carried by the board are interrupted.
Possible Causes
1. The board is configured in the network management system but it is not inserted in
the rack.
2. The link between the board and the active main control board is faulty.
Handling Procedure
1. Check whether the correct board is inserted into the corresponding slot of the base
station.
l
If yes, go to step 2.
l
If no, replace it with a correct one.
2. The board's link is broken. Cold reset the board. If the alarm persists, go to step 3.
3. Replace the board.
SJ-20111008094748-008|2012–05–30 (R1.1)
2-62
ZTE Proprietary and Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents