10013 Module Status Error; 10014 Changeover Completed - Zte ZXMW NR8250 Manual

Digital microwave transmission system
Table of Contents

Advertisement

Possible Causes
The module has been reset
Handling Procedure
None

3.7 10013 Module status error

Notification Property
l
Notification Code: 10013
l
Notification Information: The opposite-end board status is abnormal. The status is
obtained by reading signals on the signal cable via bottom-layer BSP. Such abnormal
status seldom occurs, and such exception is often used by R&D personnel to locate
the fault.
l
Notification Type: Equipment Alarm
Sub-code Description
l
Sub-code 1: The module is powered down
l
Sub-code 2: General module fault
Effect on the System
The module status is abnormal.
Possible Causes
The module's status is abnormal.
Handling Procedure
Extract and insert the board.

3.8 10014 Changeover completed

Notification Property
l
Notification Code: 10014
l
Notification Information: The active/standby RCUB board changeover is completed.
l
Notification Type: Handling Alarm
Sub-code Description
l
Sub-code 1: Initiate switchover in LMT
l
Sub-code 2: Press button for switchover
SJ-20111008094748-008|2012–05–30 (R1.1)
3-5
ZTE Proprietary and Confidential
Chapter 3 Notification

Hide quick links:

Advertisement

Table of Contents
loading