134243754 Rmep Rdi; 134243755 Ethernet Devices Cross-Connected - Zte ZXMW NR8250 Manual

Digital microwave transmission system
Table of Contents

Advertisement

Effect on the System
It does not affect the traffic carried by the board.
Possible Causes
None
Handling Procedure
Check the port of the RMEP in the alarm.

2.2.36 134243754 RMEP RDI

Alarm Property
l
Alarm Code: 134243754
l
Alarm Information: The alarm is reported if LMEP receives the CCM packet in which
the RDI information is abnormal.
l
Alarm Level: Major
l
Alarm Type: Communications Alarm
Sub-code Description
None
Effect on the System
It does not affect the traffic carried by the board. It indicates that a section or node of
the link covered in maintenance association (MA) is faulty and some traffic stream will be
interrupted.
Possible Causes
Some MEPs in the same MA has alarms.
Handling Procedure
Check the MEP in alarm in the MA for the alarm type. Remove the fault according to the
alarm type.

2.2.37 134243755 Ethernet devices cross-connected

Alarm Property
l
Alarm Code: 134243755
l
Alarm Information: The alarm is reported if LMEP receives the CCM packet from MEP
of other MA.
l
Alarm Level: Major
SJ-20111008094748-008|2012–05–30 (R1.1)