134217730 Rtc Clock Alarm - Zte ZXMW NR8250 Manual

Digital microwave transmission system
Table of Contents

Advertisement

Possible Causes
1. The IP address of the SNTP server is set incorrectly.
2. The SNTP server fails.
3. The network is faulty.
4. The RCU board is faulty.
Handling Procedure
In the LMT system:
1. Ensure that the SNTP Server IP Address on the SNTP management page is set
correctly. (Path: Setup > System > Time).
2. Set SNTP Mode and SNTP Clock Synchronization Service, and then click Apply. If a
dialog box appears to indicate that the operation fails, ensure that the SNTP server is
operating properly.
3. Check the communication quality between NE and SNTP server to ensure that the NE
can be accessed through the SNTP server.
4. If the alarm persists after the preceding steps, replace the faulty RCU board.

2.1.6 134217730 RTC clock alarm

Alarm Property
l
Alarm Code: 134217730
l
Alarm Information: The alarm is reported if the master RTC clock timing fails.
l
Alarm Level: Minor
l
Alarm Type: Equipment Alarm
Sub-code Description
l
Sub-code 1: RTC clock failure;
l
Sub-code 2: RTC clock not set.
Effect on the System
The system time is not accurate. When this alarm is reported, the system enters the soft
timing status and the system timescale precision decreases.
Possible Causes
1. RTC clock chip failure;
2. The RTC clock chip is not initialized.
Handling Procedure
1. Set the clock parameters.
2. Check if the required battery is available on the RCU board.
SJ-20111008094748-008|2012–05–30 (R1.1)
2-5
ZTE Proprietary and Confidential
Chapter 2 Alarm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents