134243766 1588 Clock Ptp Link Abnormal - Zte ZXMW NR8250 Manual

Digital microwave transmission system
Table of Contents

Advertisement

ZXMW NR8250 Alarm and Notification Handling Reference
l
Alarm Type: Equipment Alarm
Sub-code Description
None
Effect on the System
The conversation connection setup fails, and the opposite-end master clock source of the
conversation cannot be taken as the current synchronization master clock source.
Possible Causes
The PTP configuration is incorrect or the network is abnormal.
Handling Procedure
1. Ensure that the slave device configurations such as the destination address and PTP
configuration.
2. Check whether the PTP configuration of the slave device and master device are
correct.
l
If yes, go to step 2.
l
If no, modify the PTP configuration, such as the destination address and VLAN
information.
3. Check the network connections between the slave device and the master device.

2.1.20 134243766 1588 clock PTP link abnormal

Alarm Property
l
Alarm Code: 134243766
l
Alarm Information: The alarm is reported if a PTP link has serious packet loss problem.
l
Alarm Level: Minor
l
Alarm Type: Equipment Alarm
Sub-code Description
None
Effect on the System
The 1588 slave clock link detects that the link becomes abnormal due to serious packet loss
problem. The master link alarm may cause 1588 master/slave link changeover. A slave
link that has the alarm is not selected as the link to which the changeover is performed.
Possible Causes
l
The threshold setting is not reasonable.
l
Network problems occur, for example, the cable is faulty.
SJ-20111008094748-008|2012–05–30 (R1.1)