134237931 Optical Module Not In Position; 134237932 Optical Module Shut Down - Zte ZXMW NR8250 Manual

Digital microwave transmission system
Table of Contents

Advertisement

Effect on the System
SNCP route setting failure causes the service on this route to interrupt.
Possible Causes
The SNCP route setting fails.
Handling Procedure
Make the SNCP route take effect again.

2.1.13 134237931 Optical module not in position

Alarm Property
l
Alarm Code: 134237931
l
Alarm Information: The alarm is reported if the optical module is not in position or
damaged.
l
Alarm Level: Critical
l
Alarm Type: Equipment Alarm
Sub-code Description
l
Sub-code 1: Optical port 1 on the RTUB board;
l
Sub-code 2: Optical port 2 on the RTUB board.
Effect on the System
The optical module not in position may cause the service via the port to interrupt.
Possible Causes
1. Optical module is not inserted.
2. Optical module is faulty.
Handling Procedure
Check whether the optical module is inserted.
l
If yes, replace the optical module.
l
If no, insert the optical module.

2.1.14 134237932 Optical module shut down

Alarm Property
l
Alarm Code: 134237932
l
Alarm Information: The alarm is reported if the optical module is shut down.
l
Alarm Level: Minor
SJ-20111008094748-008|2012–05–30 (R1.1)
2-11
ZTE Proprietary and Confidential