134243733 Ospf Interface Status Changed; 134243734 Ospf Virtual Interface Status Changed - Zte ZXMW NR8250 Manual

Digital microwave transmission system
Table of Contents

Advertisement

3.16 134243733 OSPF interface status changed

Notification Property
l
Notification Code: 134243733
l
Notification Information: The notification is reported if the OSPF interface status is
changed.
l
Notification Type: Handling Alarm
Sub-code Description
None
Effect on the System
None
Possible Causes
The OSPF interface status is changed.
Loopback, Down, Waiting, PTP, Backup, DROther, and DR.
Handling Procedure
No processing is required.

3.17 134243734 OSPF virtual interface status changed

Notification Property
l
Notification Code: 134243734
l
Notification Information: The alarm is reported if the OSPF virtual interface status is
changed.
l
Notification Type: Handling Alarm
Sub-code Description
None
Effect on the System
None
Possible Causes
The OSPF virtual interface status is changed. All OSPF interface status packets include:
Loopback, Down, Waiting, PTP, Backup, DROther, and DR.
SJ-20111008094748-008|2012–05–30 (R1.1)
All OSPF interface status packets include:
3-11
ZTE Proprietary and Confidential
Chapter 3 Notification