134237928 Hp-Rdi - Zte ZXMW NR8250 Manual

Digital microwave transmission system
Table of Contents

Advertisement

ZXMW NR8250 Alarm and Notification Handling Reference
Sub-code Description
Each subcode represents a timeslot. The former 63 timeslots are used for optical port
1,and the latter 63 timeslots are used for optical port 2.
Effect on the System
All the relay receive signals transmitted on the SDH link may be interrupted.
Possible Causes
1. The signals sent from the upstream equipment to NR8250 equipment contains the
TU-LOP signal.
2. The RTUB board that reports the alarm is faulty.
Handling Procedure
1. Ensure that the signal sent from the upstream equipment to the NR8250 equipment
does not contain the TU-LOP signal.
2. Check whether the clock configuration is correct.
l
If yes, go to step 3.
l
If no, configure the clock again.
3. The alarm is caused by RTUB board failure. Replace the board.s

2.2.22 134237928 HP-RDI

Alarm Property
l
Alarm Code: 134237928
l
Alarm Information: The local end detects the HP-TIM or HP-SLM signal.
l
Alarm Level: Major
l
Alarm Type: Communications Alarm
Sub-code Description
l
Sub-code 1: STM-1 of optical port 1 (LMT displays "STM-1");
l
Sub-code 5: Path 1 of optical port 2 (LMT displays "STM-4-Channel1");
l
Sub-code 6: Path 2 of optical port 2 (LMT displays "STM-4-Channel2");
l
Sub-code 7: Path 3 of optical port 2 (LMT displays "STM-4-Channel3");
l
Sub-code 8: Path 4 of optical port 2 (LMT displays "STM-4-Channel4");
l
Sub-code 10: STM-1 of optical port 2 (LMT displays "2STM-1").
Effect on the System
The receive signal transmitted on the SDH link is interrupted.
Possible Causes
1. The upstream equipment receives AU-AIS, AU-LOP, HP-PLM, or HP-UNEQ alarm.
SJ-20111008094748-008|2012–05–30 (R1.1)
2-40
ZTE Proprietary and Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents