Master Spray/Hold
Switch Connection
6. Connect the orange wire from the Parallel AccuBoom Cable P/N 115-
b. Connect the high current power wire (10 ga red wire in Parallel
AccuBoom Cable P/N 115-0171-598) to a fused connection from
the fuse box.
c. Connect the logic power wire (small red wire in Parallel
Accuboom Cable P/N 115-0171-598) to a source of clean switched
power.
0171-598 to the master boom enable switch on the machine.
a. Pull the joystick cable connectors out from under the side console.
b. Identify the master spray/hold switch connector.
c. Disconnect the two pin weatherpac connectors.
d. Plug in the orange "Tee" connector from the Parallel AccuBoom
Cable P/N 115-0171-598 into the weatherpac connectors.
e. Return the wires and connectors to their location under the side
console.