Table of Contents

Advertisement

Available languages

Available languages

WWW.ZEPHYRONLINE.COM
Tempest II
AK7500CS, AK7536CS, AK7542CS,
AK7548CS, AK7554CS
EN Use, Care, and Installation Guide
FR Guide d'utilisation, d'entretien et d'installation
C
TM
Airflow Control Technology
OCT20.0301

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr Tempest II AK7500CS

  • Page 1 WWW.ZEPHYRONLINE.COM Tempest II AK7500CS, AK7536CS, AK7542CS, AK7548CS, AK7554CS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation Airflow Control Technology OCT20.0301...
  • Page 2 P R O T E M P E S T I I U N D E R - C A B I N E T Tempest II Use, Care, and Installation Guide...
  • Page 3: Table Of Contents

    Contents ZEPHYRONLINE.COM Page Safety Information ................4-9 Types of Safety Warnings ..............4 General Safety ..................5-8 Operation ................... 8 Electrical Requirements ..............8-9 Federal Communication Commission Interface Statement ....9 List of Materials .................. 10 Installation Instructions ..............11-24 Ducting Calculation Sheet ..............11 Mounting Height, Clearance, &...
  • Page 4: Safety Information

    P R O Safety Information T E M P E S T I I U N D E R - C A B I N E T Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages.
  • Page 5: General Safety

    Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS General Safety WARNING To reduce the risk of fire or electric shock, do not use this fan with any solid-state control device. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer.
  • Page 6 P R O Safety Information T E M P E S T I I U N D E R - C A B I N E T READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings.
  • Page 7 Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 8: Operation

    P R O Safety Information T E M P E S T I I U N D E R - C A B I N E T READ AND SAVE THESE INSTRUCTIONS CAUTION To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.
  • Page 9: Federal Communication Commission Interface Statement

    Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product. A cable locking connector (not supplied) might also be required by local codes.
  • Page 10: List Of Materials

    P R O List of Materials T E M P E S T I I U N D E R - C A B I N E T Parts Supplied Quantity Part Hood Pro baffle filters (AK7500CS, AK7536CS, AK7542CS) Pro baffle filters (AK7548CS & AK7554CS) LumiLight LED, 6W (pre-installed) LumiLight LED, 6W (pre-installed) (only AK7548CS &...
  • Page 11: Installation Instructions

    Installation Instructions ZEPHYRONLINE.COM Ducting Calculation Sheet Equivalent number Duct pieces Equivalent number Duct pieces length x used Total Total length x used 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6”...
  • Page 12: Mounting Height, Clearance, & Ducting

    P R O Installation Instructions T E M P E S T I I U N D E R - C A B I N E T Mounting Height, Clearance, & Ducting i n . ” m ” m ” Tempest II Use, Care, and Installation Guide...
  • Page 13 Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 8” round must be used to maintain maximum air flow efficiency for single blower and 10” round duct for dual blower for both horizontal and vertical ducting. A 3-1/4” x 10” rectangular duct may also be used for single blowers for horizontal ducting Always use rigid type metal ducts only.
  • Page 14: Ducting Options

    P R O Installation Instructions T E M P E S T I I U N D E R - C A B I N E T Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option.
  • Page 15 Installation Instructions ZEPHYRONLINE.COM Top View Side View **7-7/8” **9-1/2” 2-3/4” ***10-3/8” ***14-3/16” 1-3/4” **1-15/16” 6” ***4-5/16” **7-7/8” 8-9/16” 12” ***10-3/8” 18” 1-1/16” 11-9/16” **7-7/8” 4” ***9-15/16” R 9/16” 24” 29-7/8” (30”) 35-7/8” (36”) 41-7/8“ (42”) 47-7/8” (48”) 53-7/8” (54”) Back View Back View Mounting Dimensions Ducting &...
  • Page 16: Electrical Supply

    P R O Installation Instructions T E M P E S T I I U N D E R - C A B I N E T Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring.
  • Page 17: Mounting The Hood

    Installation Instructions ZEPHYRONLINE.COM Mounting the Hood CAUTION 4” wood board At least two installers are required due to the weight and size of the hood. ” 1. Select preferred ducting application (vertical or horizontal) and prepare hood. Refer to page 11 for single blower horizontal ducting, page 13 for dual blower vertical ducting or page 14 for dual blower horizontal ducting.
  • Page 18 P R O Installation Instructions T E M P E S T I I U N D E R - C A B I N E T Mounting the Hood 7. Prepare electrical wiring and electrical cut outs in upper cabinet if needed or wall if horizontal electrical hook up is required.
  • Page 19: Horizontal Ducting Conversion

    Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Conversion This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8” round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below. 1.
  • Page 20 P R O Installation Instructions T E M P E S T I I U N D E R - C A B I N E T Horizontal Ducting Conversion 4. Remove (4) screws attaching blower to blower plate. Turn blower 180 degrees and reattach to blower plate.
  • Page 21 Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Conversion 7. From inside hood body, position top cover plate to top of hood body. From outside hood body, attach top cover plate to top of hood body using (4) 3/16 x 3/8 screws. 8. Connect blower plug. Tempest II Use, Care, and Installation Guide...
  • Page 22: Pbd-1200A Dual Blower Vertical Ducting

    P R O Installation Instructions T E M P E S T I I U N D E R - C A B I N E T PBD-1200A Dual Blower Vertical Ducting This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below.
  • Page 23 Installation Instructions ZEPHYRONLINE.COM PBD-1200A Dual Blower Vertical Ducting 4. Attach single blower to dual blower plate by (4) previously removed screws from step 3. 5. Position dual blower inside hood body as shown. Be sure to tuck dual blower plate into blower plate tabs.
  • Page 24: Pbd-1200A Dual Blower Horizontal Ducting

    P R O Installation Instructions T E M P E S T I I U N D E R - C A B I N E T PBD-1200A Dual Blower Horizontal Ducting Follow Steps 1 through 4 on page 22-23, then continue PBD-1200A horizontal ducting installation by following the steps below.
  • Page 25: Features & Controls

    Features & Controls ZEPHYRONLINE.COM Touch Controls Blower On/Off Display (speed level, delay off, filter clean) Lights Low/High/Off Adjust 6 Speed Levels 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. ACT Verification - Airflow Control Technology (ACT) allows the installer to set the maximum blower CFM to align with local codes and regulations.
  • Page 26: Touch Controls

    P R O Features & Controls T E M P E S T I I U N D E R - C A B I N E T Touch Controls Charcoal Filter Change Reminder (charcoal filter, if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home.
  • Page 27 Features & Controls ZEPHYRONLINE.COM Touch Controls Baffle Filter Clean Reminder A set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean.
  • Page 28: Optional Rf Remote Control

    P R O Features & Controls T E M P E S T I I U N D E R - C A B I N E T Optional RF Remote Control FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
  • Page 29 The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. D. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
  • Page 30: Maintenance

    P R O Maintenance T E M P E S T I I U N D E R - C A B I N E T Hood & Filter Cleaning Surface Maintenance Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride.
  • Page 31 Maintenance ZEPHYRONLINE.COM 1. Push filter toward back of range hood using handles. 2. Pivot front of filter downward. 3. Remove filter by pulling away from hood. Hood Model Part Number Qty. to Order AK7500CS 50210039 AK7536CS 50210039 AK7542CS 50210039 AK7548CS 50210039 AK7554CS 50210039...
  • Page 32: Lumilight Led

    U N D E R - C A B I N E T LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information.
  • Page 33: Act™ Conversion

    Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels, 390 or 290 CFM.
  • Page 34: Enabling Act

    P R O ACT™ Conversion T E M P E S T I I U N D E R - C A B I N E T Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. H. 2.
  • Page 35 ACT™ Conversion ZEPHYRONLINE.COM Enabling ACT™ Model: AK75 - PC board located behind the light panel. - Remove baffle filters. - Remove both side spacer panels (if applicable) by 2 screws for each spacer panel. - Remove 4 screws attaching light panel. FIG.
  • Page 36: Wiring Diagram

    P R O Wiring Diagram T E M P E S T I I U N D E R - C A B I N E T AK7500CS, AK7536CS & AK7542CS CIRCUIT DIAGRAM WHITE YELLOW GREY MOTOR BROWN BLUE GREEN BODY WHITE BLUE...
  • Page 37 Wiring Diagram ZEPHYRONLINE.COM AK7548CS & AK7554CS CIRCUIT DIAGRAM WHITE YELLOW GREY MOTOR BROWN BLUE GREEN BODY WHITE BLUE BROWN GREY MOTOR YELLOW GREEN BODY BODY TRANSFORMER ACT 390 CFM - Fan Max. 365W @ 3.1A ACT 290 CFM - Fan Max. 290W @ 2.4A Tempest II Use, Care, and Installation Guide...
  • Page 38: Troubleshooting

    P R O Troubleshooting T E M P E S T I I U N D E R - C A B I N E T Possible Problem Possible Cause Solutions After installation, the The power source is not turned ON. Make sure the circuit breaker and the unit’s unit doesn’t work.
  • Page 39 Troubleshooting ZEPHYRONLINE.COM Possible Problem Possible Cause Solutions The hood is not venting Using the wrong size of ducting. Change the ducting to the correct size out properly. The hood might be hanging to high Adjust the distance between the cook top from the cook top.
  • Page 40: List Of Parts & Accessories

    P R O List of Parts & Accessories T E M P E S T I I U N D E R - C A B I N E T Description Part Number Replacement Parts LumiLight LED, 6W Z0B0048 Pro Baffle Filter (each) 50210039 RF Remote Control 14000005...
  • Page 41: Notes

    Notes ZEPHYRONLINE.COM Tempest II Use, Care, and Installation Guide...
  • Page 42 P R O Notes T E M P E S T I I U N D E R - C A B I N E T Tempest II Use, Care, and Installation Guide...
  • Page 43: Limited Warranty

    Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
  • Page 44: Product Registration

    Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368 Tempest II Use, Care, and Installation Guide...
  • Page 45 WWW.ZEPHYRONLINE.COM Tempest II AK7500CS, AK7536CS, AK7542CS, AK7548CS, AK7554CS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation Airflow Control Technology OCT20.0301...
  • Page 46 P R O T E M P E S T I I S O U S - A R M O I R E Tempest II Guide d’utilisation, d’entretien et d’installation...
  • Page 47 Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ............... 4-9 Types d’avertissements de sécurité ............. 4 Sécurité générale ................5-8 Opération ................... 8 Exigences électriques ................8-9 Déclaration d’interface de la Federal Communication Commission ... 9 Liste de matériel ................. 10 Instructions d’installation ..............11-25 Feuille de calcul pour le conduit d’aération .........
  • Page 48: Consignes De Sécurité

    P R O Consignes de sécurité T E M P E S T I I S O U S - A R M O I R E Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps.
  • Page 49: Sécurité Générale

    Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS Sécurité générale ATTENTION Pour réduire le risque d’incendie ou de choc électrique, n’utilisez pas ce ventilateur avec un dispositif de commande à semi- conducteurs. ATTENTION AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ LES SUIVANTS: a) N’utilisez cet appareil que de la manière prévue par le fabricant.
  • Page 50 P R O Consignes de sécurité T E M P E S T I I S O U S - A R M O I R E LISEZ ET CONSERVEZ CES INSTRUCTIONS ATTENTION AVERTISSEMENT - POUR RÉDUIRE LE RISQUE D’INCENDIE DE GRAISSE SUR LE HAUT DE CUISINIÈRE: a) Ne laissez jamais les unités de surface sans surveillance à...
  • Page 51 Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS ATTENTION AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ CE QUI SUIT: a) Les travaux d’installation et le câblage électrique doivent être effectués par des personnes qualifiées conformément à...
  • Page 52: Opération

    P R O Consignes de sécurité T E M P E S T I I S O U S - A R M O I R E LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT Pour réduire les risques d’incendie et pour évacuer correctement l’air extérieur, ne pas évacuer l’air évacué...
  • Page 53: Déclaration D'interface De La Federal Communication Commission

    Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS Cet appareil nécessite une alimentation électrique de 120 V à 60 Hz et est connecté à un circuit de dérivation individuel correctement mis à la terre protégé par un disjoncteur de 15 ou 20 ampères ou un fusible temporisé.
  • Page 54: Liste De Matériel

    P R O Liste de matériel T E M P E S T I I S O U S - A R M O I R E Pièces fournies Quantité Partie Hotte Filtres à chicane pro (AK7500CS, AK7536CS, AK7542CS) Filtres à chicane pro (AK7548CS et AK7554CS) LumiLight LED, 6 W (pré-installé) LumiLight LED, 6W (pré-installé) (uniquement AK7548CS et AK7554CS) Col de départ rond de 8 po...
  • Page 55: Instructions D'installation

    Instructions d’installation ZEPHYRONLINE.COM Feuille de calcul pour le conduit d’aération Longueur x Longueur x Pièces de conduit Pièces de conduit T otal T otal Nombre utilisé Nombre utilisé 3- 1/ 4” x 10” 1 pi 6” circ. à 5 pi rect., droit rect.
  • Page 56: Hauteur De Montage, Dégagement Et Gaine

    P R O Instructions d’installation T E M P E S T I I S O U S - A R M O I R E Hauteur de montage, dégagement et gaine Tempest II Guide d’utilisation, d’entretien et d’installation...
  • Page 57 Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine Un minimum de 8 po rond doit être utilisé pour maintenir une efficacité maximale du débit d’air pour un seul ventilateur et un conduit rond de 10 po pour un double ventilateur pour les conduits horizontaux et verticaux.
  • Page 58: Options De Conduits

    P R O Instructions d’installation T E M P E S T I I S O U S - A R M O I R E Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages.
  • Page 59 Instructions d’installation ZEPHYRONLINE.COM Vue de dessus Vue de côté **7-7/8 po **9-1/2 po 2-3/4 po ***10-3/8 po ***14-3/16 po 1-3/4 po **1-15/16 po ***4-5/16 po 6 po **7-7/8 po 8-9/16 po 12 po ***10-3/8 po 18 po 1-1/16 po 11-9/16 po **7-7/8 po 4 po ***9-15/16 po...
  • Page 60: Fourniture Électrique

    P R O Instructions d’installation T E M P E S T I I S O U S - A R M O I R E Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à...
  • Page 61: Montage De La Hotte

    Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte AVERTISSEMENT 4 po planche de bois Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la hotte. 1. Sélectionnez l’application de conduit préférée (verticale ou horizontale) et préparez la hotte. Reportez-vous à...
  • Page 62 P R O Instructions d’installation T E M P E S T I I S O U S - A R M O I R E Mounting the Hood 7. Préparez le câblage électrique et les découpes électriques dans l’armoire supérieure si nécessaire ou au mur si un raccordement électrique horizontal est nécessaire.
  • Page 63: Conversion De Conduit Horizontal

    Instructions d’installation ZEPHYRONLINE.COM Conversion de conduit horizontal Cette hotte de cuisinière est équipée de série d’une option de conduit vertical rond de 8 po. Pour convertir un conduit vertical rond de 8 po à un conduit horizontal rond de 8 po ou un conduit horizontal rectangulaire de 3-1/4 po x 10 po, veuillez suivre les instructions ci-dessous.
  • Page 64 P R O Instructions d’installation T E M P E S T I I S O U S - A R M O I R E Conversion de conduit horizontal 4. Retirez les (4) vis fixant le ventilateur à la plaque du ventilateur.
  • Page 65 Instructions d’installation ZEPHYRONLINE.COM Conversion de conduit horizontal 7. Depuis l’intérieur du corps de la hotte, placez la plaque de recouvrement supérieure vers le haut du corps de la hotte. Depuis l’extérieur du corps de la hotte, fixez la plaque de recouvrement supérieure au dessus du corps de la hotte à...
  • Page 66: Conduit Vertical À Double Ventilateur Pbd-1200A

    P R O Instructions d’installation T E M P E S T I I S O U S - A R M O I R E Conduit vertical à double ventilateur PBD-1200A Cette hotte de cuisinière est équipée de série d’une option de conduit vertical à un seul ventilateur. Pour passer d’un conduit vertical à...
  • Page 67 Instructions d’installation ZEPHYRONLINE.COM Conduit vertical à double ventilateur PBD-1200A 4. Fixez le ventilateur simple à la plaque du ventilateur double à l’aide des (4) vis précédemment retirées de l’étape 3. 5. Positionnez le double ventilateur à l’intérieur du corps de la hotte comme illustré.
  • Page 68: Conduit Horizontal À Double Ventilateur Pbd-1200A

    P R O Instructions d’installation T E M P E S T I I S O U S - A R M O I R E Conduit horizontal à double ventilateur PBD-1200A Suivez les étapes 1 à 4 à la page 22-23, puis poursuivez l’installation du conduit horizontal PBD-1200A en suivant les étapes ci-dessous.
  • Page 69: Fonctionnalités Et Commandes

    Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles Ventilateur Marche/Arrêt Afficheur (Vitesse, arrêt à retardement, nettoyage des filtres) Lumière: faible, élevée, désactivée Choix de 6 vitesses Arrêt à retardement (5 min.) 1. Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous l’allumez, le ventilateur se met en marche à...
  • Page 70: Commandes Tactiles

    P R O Fonctionnalités et commandes T E M P E S T I I S O U S - A R M O I R E Commandes tactiles Indicateur de changement des filtres à charbon (si installés) Lorsque la hotte est installée en mode de récupération d’air, elle est munie d’un jeu de filtres à...
  • Page 71 Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson. Ils ne nécessitent aucun remplacement sur une base régulière, mais ils doivent être gardés propres.
  • Page 72: Télécommande Rf En Option

    P R O Fonctionnalités et commandes T E M P E S T I I S O U S - A R M O I R E Télécommande RF en option Attention FCC Pour assurer la conformité continue, tout changement ou modification non expressément approuvé par la partie responsable de la conformité...
  • Page 73 La télécommande RF est équipée d’un aimant à l’arrière pour un rangement facile. La télécommande peut être placée sur n’importe quelle surface magnétique telle qu’un réfrigérateur ou le support de télécommande Zephyr, FIG. D. Le support à distance peut être inséré dans une prise électrique standard pour un rangement facile.
  • Page 74: Entretien

    P R O Entretien T E M P E S T I I S O U S - A R M O I R E Entretien de surface N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. N’utilisez aucun produit contenant un agent de blanchiment chloré...
  • Page 75 Entretien ZEPHYRONLINE.COM 1. Poussez le filtre vers l’arrière de la hotte à l’aide des poignées. 2. Faites pivoter l’avant du filtre vers le bas. 3. Retirez le filtre en l’éloignant de la hotte. Modèle de capot Numéro Quantité d’article AK7500CS 50210039 AK7536CS 50210039...
  • Page 76: Lumilight Led

    S O U S - A R M O I R E LumiLight LED Dans le cas peu probable où votre LumiLight LED tombe en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la page de la liste des pièces et accessoires pour les numéros de pièces et les coordonnées.
  • Page 77: Conversion Act

    ACT™ vous permet de contrôler le CFM maximum du ventilateur de certaines hottes de cuisinière Zephyr Ventilation sans avoir besoin de kits d’air d’appoint coûteux. ACT™ permet à l’installateur de régler facilement la vitesse maximale du ventilateur à l’un des deux niveaux de CFM les plus couramment spécifiés, 390 ou 290 CFM.
  • Page 78: Activer Act

    P R O Conversion ACT™ T E M P E S T I I S O U S - A R M O I R E Activer ACT™ Pour activer ACT™: 1. Avant l’installation de la hotte, accédez au tableau de circuits imprimés en suivant les étapes illustrées à...
  • Page 79 Conversion ACT™ ZEPHYRONLINE.COM Activer ACT™ Modèle: AK75 - Carte électronique située derrière le panneau lumineux. - Retirez les filtres déflecteurs. - Retirez les deux panneaux d'entretoise latéraux (le cas échéant) par 2 vis pour chaque panneau d'entretoise. - Retirez les 4 vis de fixation du panneau lumineux. FIG.
  • Page 80: Schéma De Câblage

    P R O Schéma de câblage T E M P E S T I I S O U S - A R M O I R E AK7500CS, AK7536CS & AK7542CS SCHÉMA ROUGE BLANC ROUGE JAUNE GRIS MOTEUR MARRON BLEU VERT CORPS ROUGE...
  • Page 81 Schéma de câblage ZEPHYRONLINE.COM AK7548CS & AK7554CS SCHÉMA ROUGE BLANC ROUGE JAUNE GRIS MOTEUR MARRON BLEU VERT CORPS ROUGE BLANC BLEU MARRON GRIS MOTEUR ROUGE JAUNE VERT CORPS CORPS TRANSFORMATEUR ACT 390 CFM - Ventilateur Max. 365 W à 3,1 A ACT 290 CFM - Ventilateur Max.
  • Page 82: Dépannage

    P R O Dépannage T E M P E S T I I S O U S - A R M O I R E Problème possible Cause possible Solutions Après l'installation, La source d'alimentation n'est pas Assurez-vous que le disjoncteur et l’appareil l'unité...
  • Page 83 Dépannage ZEPHYRONLINE.COM Problème possible Cause possible Solutions La hotte ne s'échappe Utilisation de la mauvaise taille de Changer la gaine à la bonne taille pas correctement. conduit. La hotte est peut-être suspendue Ajustez la distance entre la table de cuisson trop haut de la table de cuisson.
  • Page 84: Liste Des Pièces Et Accessoires

    P R O Liste des pièces et accessoires T E M P E S T I I S O U S - A R M O I R E La description Numéro d’article Pièces de rechange LumiLight LED, 6 W Z0B0048 Filtre déflecteur pro (chacun) 50210039...
  • Page 85: Remarques

    Remarques ZEPHYRONLINE.COM Tempest II Guide d’utilisation, d’entretien et d’installation...
  • Page 86 P R O Remarques T E M P E S T I I S O U S - A R M O I R E Tempest II Guide d’utilisation, d’entretien et d’installation...
  • Page 87: Garantie Limitée

    Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...
  • Page 88: Enregistrement Du Produit

    À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire. Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368 Tempest II Guide d’utilisation, d’entretien et d’installation...

Table of Contents