Download Print this page

Advertisement

www.zephyronline.com
Tempest II
AK7500BS
AK7536BS
AK7542BS
AK7548BS
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
JUN15.0301 © 2015 Zephyr Ventilation LLC.
READ AND SAVE THESE INSTRUCTIONS

Advertisement

loading

Summary of Contents for Zephyr AK7500BS

  • Page 1 Tempest II AK7500BS AK7536BS AK7542BS AK7548BS Model number: Serial Number: Date of Purchase: Sales Dealer: JUN15.0301 © 2015 Zephyr Ventilation LLC. READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
  • Page 3: Damage - Shipment/Installation

    www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could mounted too high will be hard to reach and will If available, also refer range manufacturer’s height i n .
  • Page 4 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Some Ducting Options Roof Pitch w/ Flashing & Cap Side wall cap w/ gravity damper Soffit or crawl space...
  • Page 5: Top View

    www.zephyronline.com Top View Side View **7 7/8” **9 1/2” 2 3/4” ***10 3/8” ***14 3/16” 1 3/4” **1 15/16” 6” ***4 5/16” **7 7/8” 8 9/16” 12” ***10 3/8” 18” 1 1/16” 11 9/16” **7 7/8” 4” ***9 15/16” R 9/16” 24”...
  • Page 6 ELECTRICAL WARNING how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
  • Page 7 5. Mark center line of wood board. Center and align top of board with 26” Wood Board Dimensions AK7500BS - 27” x 1/2” x 4” AK7536BS - 33” x 1/2” x 4” AK7542BS - 39” x 1/2” x 4” AK7548BS - 45” x 1/2” x 4”...
  • Page 8 This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8” round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below. VERTICAL TO HORIZONTAL DUCTING CONVERSION 1.
  • Page 9 www.zephyronline.com 5. Position single blower with single blower plate 6. Attach 8” round duct collar or 3 1/4”x10” as shown. Be sure to tuck back of single blower rectangular duct collar to back of hood body plate into tabs at back of hood. Secure single removed from step 2.
  • Page 10 This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below. 1. Disconnect blower plug. attaching single blower plate to top of hood body.
  • Page 11 www.zephyronline.com Follow Steps 1 through 4 on page 13, then continue PBD-1200A horiztantal ducting installation by following the steps below. 5. Knock out plate A for dual blower horizontal 6. Position dual blower inside hood body. Attach by ducting. 7. From inside hood body, position top cover plate 8.

This manual is also suitable for:

Ak7536bsAk7542bsAk7548bsTempest ii