WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS
FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions,
contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel
to prevent power from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials
and vapors. Take care when using cleaning agents or detergents.
Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking
and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b. Always turn hood ON when cooking at high heat or when flaming food
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate
on fan or filter.
d. Use proper pan size. Always use cookware appropriate for the size of the surface
element.
e. Keep fan, filters and grease laden surfaces clean.
f. Use high setting on hood only when necessary.
g. Don't leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food
being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP
FIRE, OBSERVE THE FOLLOWING:
a.
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then
turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b.
NEVER PICK UP A FLAMING PAN – You may be burned.
c.
DO NOT USE WATER, including wet dishcloths or towels – a violent steam
explosion will result.
DEC05.0101
d.
to operate it.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by qualified person (s) in
accordance with all applicable codes and standards. Including fire-rated construction.
b. Sufficient air is needed for power combustion and exhausting of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer's guideline and safety standards such as those published
by the National Fire Protection Association (NFPA) and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
c. When cuttig or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCL (Ground Fault Interrupter protected branch circuit).
g. NEVER place a switch where it can be reached from a tub or shower.
h. Make sure the power is off before installing, wiring or maintenancing.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into
spaces within walls, ceilings, attics, crawl spaces or garages.
WARNING
TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN
ISOLATING WALL CONTROL/SWITCH.
OPERATION
Always leave safety grills and filters in place. Without these components, operating
blowers could catch onto hair, fingers and loose clothing.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom
work.
www.zephyronline.com
7500 series
Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr AK 7500 series

  • Page 1 7500 series Use an extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and you already know how to operate it. 2. The fire is small and contained in the area where it started. 3. The fire department is being called. WARNING 4.
  • Page 3: Installation

    INSTALLATION INSTALLATION MOUNT HEIGHTS DUCTING Minimum mount height between range top to WARNING FIRE HAZARD hood bottom should be no less than 24". 12" NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or Maximum mount height should be no higher garages.
  • Page 4: Specifications

    INSTALLATION INSTALLATION SPECIFICATIONS MOUNTING THE RANGEHOOD ELECTRICAL 12" WARNING Elec K.O. All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
  • Page 5 INSTALLATION INSTALLATION MOUNTING THE RANGEHOOD MOUNTING THE RANGEHOOD 5. Install electrical. 1. Begin by determining hood mounting height on wall. 6. Install duct work and tape all joints. 7. Power up hood and check for leaks around duct joints, and if necessary apply more duct tape. duct/silver tape 2.
  • Page 6: Controls And Features

    CONTROLS & FEATURES MAINTENANCE CONTROLS & FEATURES CLEANING Auto Mode Indicator Surface Maintenance: Manual Mode Indicator Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive Lights On/Off Indicator detergent (e.g. comet powder scrub, EZ-Off oven cleaner), or steel wool/scoring pads which will Delay Off Indicator scratch and damage surface.
  • Page 7: Warranty

    Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr's Authorized Agents. What is Not Covered: OPTIONAL ACCESSORIES Consumable parts such as light bulbs, filters, and fuses.
  • Page 8 Or write to: shuts the motor down. 3. Change the condenser. 3. Damaged condenser. Zephyr Corporation 4. Make sure the Blue wire on control board 4. The Blue wire on the control board is disconnected. is connected properly.

Table of Contents