Available languages

www.zephyronline.com
Tempest II
AK7500BS
AK7536BS
AK7548BS
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
APR14.0201 © 2014 Zephyr Corporation
READ AND SAVE THESE INSTRUCTIONS

Advertisement

loading

Summary of Contents for Zephyr AK7500BS

  • Page 1 Tempest II AK7500BS AK7536BS AK7548BS Model number: Serial Number: Date of Purchase: Sales Dealer: APR14.0201 © 2014 Zephyr Corporation READ AND SAVE THESE INSTRUCTIONS...
  • Page 2 www.zephyronline.com...
  • Page 3: Table Of Contents

    SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options .......................... Electrical ................. Mounting the Range Hood ........Single Blower Horizontal Ducting Conversion 11-12 PBD-1200A Dual Blower Vertical Ducting ..PBD-1200A Dual Blower Horizontal Ducting FEATURES &...
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
  • Page 6: Installation

    M4 x 8 (8) Wire Caps (3) PARTS NOT SUPPLIED - Ducting, conduit and all installation tools - Duct Cover Accessory AK7500BS - 27” x 1/2” x 4” AK7536BS - 33” x 1/2” x 4” AK7548BS - 45” x 1/2” x 4”...
  • Page 7 Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3-1/ 4” x 10” 1 Ft. 6” Round 30 Ft. Rect., wall cap straight with damper 6” Round, 1 Ft. 6” Round, 30 Ft.
  • Page 8 www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could mounted too high will be hard to reach and will If available, also refer range manufacturer’s height i n .
  • Page 9: Ducting Options

    WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Some Ducting Options Roof Pitch w/ Flashing & Cap Side wall cap w/ gravity damper Soffit or crawl space...
  • Page 10: Electrical

    www.zephyronline.com Top View Side View **7 7/8” **9 1/2” 2 3/4” ***10 3/8” ***14 3/16” 1 3/4” **1 15/16” 6” ***4 5/16” **7 7/8” 8 9/16” 12” ***10 3/8” 18” 1 1/16” 11 9/16” **7 7/8” 4” ***9 15/16” R 9/16” 24”...
  • Page 11 ELECTRICAL WARNING how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
  • Page 12 5. Mark center line of wood board. Center and align top of board with 26” Wood Board Dimensions AK7500BS - 27” x 1/2” x 4” AK7536BS - 33” x 1/2” x 4” AK7548BS - 45” x 1/2” x 4” 6. Prepare duct pipe and duct cut outs in upper cabinet if needed or page 8 for dimensions.
  • Page 13 This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8” round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below. VERTICAL TO HORIZONTAL DUCTING CONVERSION 1.
  • Page 14 www.zephyronline.com 5. Position single blower with single blower plate 6. Attach 8” round duct collar or 3 1/4”x10” as shown. Be sure to tuck back of single blower rectangular duct collar to back of hood body plate into tabs at back of hood. Secure single removed from step 2.
  • Page 15 This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below. 1. Disconnect blower plug. attaching single blower plate to top of hood body.
  • Page 16 www.zephyronline.com Follow Steps 1 through 4 on page 13, then continue PBD-1200A horiztantal ducting installation by following the steps below. 5. Knock out plate A for dual blower horizontal 6. Position dual blower inside hood body. Attach by ducting. 7. Attach top cover plate to top of hood body using 8.
  • Page 17: Lights

    Blower On/Off Display (speed level, delay off, filter clean) Lights On/Dim/Off Adjust 6 Speed Levels 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. ACT Verification - Airflow Control Technology (ACT) allows the installer to set the maximum blower CFM to align with local codes and regulations.
  • Page 18 www.zephyronline.com Charcoal Filter Change Reminder (charcoal filter, if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home. These charcoal filters are required to be replaced after every 120 hours of use.
  • Page 19 Baffle Filter Clean Reminder Aa set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Baffle- Filter Clean reminder function in the microprocessor will automatically indicate by a flashing when the baffle filters need to be cleaned after every 30 hours of use.
  • Page 20: Maintenance

    The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. 1. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
  • Page 21 After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless should never need replacing, they are required to be cleaned every 30 days or more often depending on cooking habits. using hood. Hood Model: Part No. Qty. to Order. AK7500BS 50210020 AK7536BS 50210020 AK7548BS 50210021 Recirculating Kit Hood Model: Part No.
  • Page 22 Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. diameter of the bulb or use a rubber/latex glove and turn counter clockwise. For Zephyr part numbers please turn to page 25 of the manual.
  • Page 23: Troubleshooting

    TROUBLESHOOTING PROCEDURES FOR TEMPEST II Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 24 MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS AK7500BS, AK7536BS Single Motor 5 Dual Motor 9 CIRCUIT DIAGRAM MAX. USE ONLY TYPE MR16, GU10, 35 W. HALOGEN LIGHT BULBS. VOLTS MAX AMPS AK7548BS...
  • Page 26: Wiring Diagrams

    Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of hoods with of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT enables the installer to easily set the maximum blower speed necessary for your installation.
  • Page 27 DESCRIPTION PART # Replacement Parts Optional Accessories Dual Internal Blower PBI-1200A *Recirculating kit only compatible with single internal blower, not dual internal blower. To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 28 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows:...
  • Page 29 Tempest II AK7500BS AK7536BS AK7548BS Numéro de modèle : Numéro de série : Date d’achat : Détaillant: APR14.0201 © 2013 Zephyr Corporation LISEZ ET CONSERVEZ CES INSTRUCTIONS...
  • Page 30 www.zephyronline.com...
  • Page 31 MISE EN GARDE DE SÉCURITÉ .....2-3 ..............LISTE DU MATÉRIEL ....................... INSTALLATION Feuille de calcul pour le conduit ................... Espace libre et hauteur de montage ................Options d’installation pour le conduit ........................................Électricité ..........................Installation de la hotte.......................
  • Page 32 www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 33 ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
  • Page 34 - Trousse de ventilateur double (PBD-1200A) - Pièces de recouvrement de conduit - Planche de bois à laquelle suspendre la hotte AK7500BS - 27” x 1/2” x 4” AK7536BS - 33” x 1/2” x 4” AK7548BS - 45” x 1/2” x 4”...
  • Page 35 Longueur x Longueur x Pièces de conduit Pièces de conduit Total Total Nombre utilisé Nombre utilisé 3-1/ 4” x 10” 1 pi 6” 30 pi rect., droit embout mural circ./registre 6” circ., droit 1 pi 6” 30 pi chapeau de toiture circ.
  • Page 36 www.zephyronline.com La hauteur de montage de la surface de la cuisinière au bas de la hotte ne devrait pas être inférieure à 26”. La hauteur de montage maximale ne devrait pas outrepasser 36”. Il est important d’installer la hotte à la hauteur de montage adéquate.
  • Page 37 AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison. N’utilisez que des conduits en métal pour cloison simple. Fixez toutes les pièces du conduit avec des vis à...
  • Page 38 www.zephyronline.com Dessus Côté **7 7/8” **9 1/2” 2 3/4” ***10 3/8” ***14 3/16” 1 3/4” **1 15/16” 6” ***4 5/16” **7 7/8” 8 9/16” 12” ***10 3/8” 18” 1 1/16” 11 9/16” **7 7/8” 4” ***9 15/16” R 9/16” 24” 29 7/8”...
  • Page 39 ÉLECTRICITÉ AVERTISSEMENT l’expérience technique et le savoir-faire nécessaires. Pour votre sécurité, enlevez le fusible ou éteignez le disjoncteur de circuit avant de commencer l’installation. N’utilisez pas de rallonge électrique ou d’adaptateur avec cet électroménager. Suivez le code électrique national ou les codes et réglementations en vigueur. Alimentation électrique : Cet appareil requiert une alimentation électrique de 120V 60Hz et doit être connecté...
  • Page 40 à des montants à l’aide de quatre (4) vis à bois M6. Dimensions de la planche de bois : (L x D x H) AK7500BS - 27” x 1/2” x 4” AK7536BS - 33” x 1/2” x 4” AK7548BS - 45” x 1/2” x 4”...
  • Page 41 Cette hotte standard est munie d’une entrée pour conduit vertical circulaire de 8”. Pour la convertir à un conduit horizontal circulaire de 8” ou rectangulaire 3-1/4” x 10”, veuillez suivre les instructions ci-dessous. CONVERSION D’UN CONDUIT VERTICAL À UN CONDUIT HORIZONTAL 2.
  • Page 42 www.zephyronline.com 5. Placez le ventilateur simple et la plaque du 6. Fixez le collier de conduit circulaire de 8” ou ventilateur simple comme illustré. Assurez-vous rectangulaire de 3-1/4”x10” à l’arrière du bâti de de réinsérer la plaque du ventilateur simple la hotte à...
  • Page 43 Cette hotte standard est munie d’une entrée pour conduit vertical avec un ventilateur simple. Pour la convertir d’un conduit vertical à ventilateur simple à un conduit vertical à ventilateur double, veuillez suivre les instructions ci-dessous. 2. Enlevez les quatre (4) vis de l’intérieur de la hotte qui retiennent la plaque du ventilateur à...
  • Page 44 www.zephyronline.com Suivez les étapes 1 à 4 de la page 13, puis continuez l’installation d’un conduit horizontal avec ventilateur PBD- 1200A en suivant les étapes ci-dessous. 6. Placez le ventilateur double à l’intérieur du bâti 5. Enlevez la plaque défonçable A pour les de la hotte.
  • Page 45 Ventilateur Marche/Arrêt Afficheur (Vitesse, arrêt à retardement, nettoyage des filtres) Lumières Allumer/Veilleuse/Éteindre Choix de 6 vitesses Arrêt à retardement (5 min.) 1. Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous l’allumez, le ventilateur se met en marche à la vitesse 1. Vérification de la TCDA - La technologie de contrôle du débit d’air permet à...
  • Page 46 www.zephyronline.com Indicateur de changement des filtres à charbon (si installés) Lorsque la hotte est installée en mode de récupération d’air, elle est munie d’un jeu de filtres à charbon conçus pour purifier la fumée de cuisson et remettre l’air en circulation dans la maison. Ces filtres à charbon doivent être remplacés toutes les 120 heures d’utilisation.
  • Page 47 Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson. Ils ne nécessitent aucun remplacement sur une base régulière, mais ils doivent être gardés propres. La fonction de rappel de nettoyage des filtres du microprocesseur indique automatiquement, à...
  • Page 48 La commande à distance radioélectrique est munie d’un aimant pour un entreposage facile. La commande peut être mise sur n’importe quelle surface magnétique, comme un réfrigérateur ou le support à commande Zephyr (FIG. 1). Le support à commande peut s’installer à une prise électrique standard pour un rechargement facile.
  • Page 49 Frottez toujours doucement, avec un chiffon de coton propre, et dans le sens du grain. nettoyés tous les 30 jours ou plus souvent, selon vos habitudes culinaires. Modèle de hotte : No de pièce Qtée à commander AK7500BS 50210020 AK7536BS 50210020 AK7548BS...
  • Page 50 Les ampoules de remplacement sont disponibles dans les magasins spécialisés en éclairage. Procurez-vous des ampoules halogènes MR-16 (GU-10) de 35 W. Consultez la page 25 du présent guide pour obtenir les numéros de pièces Zephyr.
  • Page 51 TROUBLESHOOTING PROCEDURES FOR TEMPEST II Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont fonctionne pas.
  • Page 52 www.zephyronline.com TCDA 390 pi /min — Max. du ventilateur : 365W à 3,1 A TCDA 290 pi /min — Max. du ventilateur : 290W à 2,4 A...
  • Page 54 /min qu’une hotte peut extraire. La TCDA permet de contrôler la quantité maximale de pi /min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux. La TCDA permet à l’installateur d’ajuster facilement la vitesse maximale du ventilateur à l’un des niveaux de pi /min les plus fréquemment utilisés...
  • Page 55 DESCRIPTION PART # Pièces de remplacement Ampoule MR16 (GU10) 35W (unité) Z0B-0023 Optional Accessories Ventilateur interne double PBI-1200A Trousse de recirculation d’air (30”) * ZRC-7000B Trousse de recirculation d’air (36”) * ZRC-7036B Dosseret (30”) AK0710 Dosseret (36”) AK0716 Dosseret (48”) AK0718 Recouvrement de conduit de 12”...
  • Page 56 Zephyr Corporation (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présen- tes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...

This manual is also suitable for:

Ak7536bsAk7548bsTempest ii ak7542bsTempest ii