The installation in this manual is intended for qualified installers, service technicians or persons
with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could
result from installing the unit due to lack of appropriate electrical and technical background.
All electrical wiring must be properly installed, insulated and grounded. Overly accumulated
grease in old duct work should be cleaned out or duct work should be replaced if necessary to
avoid the possibility of a grease fire. Check all joints on duct work to insure proper connection
and all joints should be properly taped.
Operations
Read all instructions in this manual before operating the appliance. Save these instructions for
future reference.
Always leave safety grills and filters in place. Without these components, operating blowers
could catch on to hair, fingers and loose clothing.
NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.
NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch fire.
The risk of self combustion is higher when the oil has been used several times.
Cleaning
The saturation of greasy residue in the blower and filters may cause increased inflammability.
Keep unit clean and free of grease and residue build-up at all times to prevent possible fires.
Filters must be cleaned periodically and free from accumulation of cooking residue (see clean-
ing instructions inside). Old and worn filters must be replaced immediately. Do not operateblow-
ers when filters are removed. Never disassemble parts to clean without proper instructions.
Disassembly is recommended to be performed by qualified personnel only. Call our service cen-
ter for removal instructions.
The manufacturer declines all responsibility in the event of failure to observe the instruc-
tions given here for installation, maintenance and suitable use of the product. The manufac-
turer further declines all responsibility for injury due to negligence and the warranty of the
unit automatically expires due to improper maintenance.
* Please check for latest specification revisions before any custom work or cutouts.
INSTALLATION
MOUNT HEIGHTS
10"
Min 24"-Max 32"
96"
36"
DUCTING
A minimum of 6" round or 3-1/4" x 10"rectangular
duct must be used to maintain maximum air flow
efficiency.
Always use rigid type metal ducts only.
Flexible ducts could restrict air flow by up to 50%.
Also use calculation (on right) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size from 6" to 7 or 8". If a reducer
is used, install a long reducer instead of a pancake
reducer. Reduce duct size as far away from open-
ing as possible.
If turns or transitions are required:
Install as far away from opening and as far
apart, between 2, as possible.
Minimum mount height between range top to
hood bottom should be no less than 24".
Maximum mount height should be no higher
than 32".
It is important to install the hood at the
proper mounting height. Hoods mounted too
low could result in heat damage and fire haz-
ard; while hoods mounted too high will be
hard to reach and will loose its performance
and efficiency.
If available, also refer range manufacturer's
height clearance requirements and recom-
mended hood mounting height above range.
Minimum Duct Size:
Round:
6" minimum
Rectangular:
3-1/4" x 10"
Duct Run Calculation:
Maximum run
6" or 3-1/4" x 10" duct
100 FT
Deduct:
each 90 Elbow used
15 FT
each 45 elbow used
9 FT
each 6" to 3/14 x 10"
transition used
1 FT
each 3/14 x 10" to 6"
each 3/14 x 10" to 6"
transition used
5 FT
Side Wall Cap w/ damper
30 FT
Roof Cap
30 FT
e.g.- 1 roof cap, 2x90 elbows, 1 x 45 elbow used:
=30' + 30' + 9' =69' used, 31' available for straight duct runs.
Models: AK7000, AK7036, AK7042 Page 1

Advertisement

loading

Summary of Contents for Zephyr AK7000

  • Page 1 USE, CARE, AND INSTALLATION GUIDE Read all Instructions before Installing and operating this appliance MOUNT HEIGHTS MODELS: AK7000, AK7036, AK7042 Tempest I Minimum mount height between range top to IMPORTANT SAFETY NOTICE hood bottom should be no less than 24".
  • Page 2: Installation

    1/2" Elec K.O. 10" 1/2" Elec K.O. 1" 4-1/2" 1-1/8" 3-1/4" 3-1/4" 10" 10" 8-5/8" 2-1/4" 10" Roof Pitch w/ 30" Flashing & Cap 36" 42" 22" Rear Ducting Models: AK7000, AK7036, AK7042 Page 2 Models: AK7000, AK7036, AK7042 Page 3...
  • Page 3: Mounting The Rangehood

    9. Install duct work and duct-tape. 10. Reinstall the baffle filters. 11. Power up hood and check for leaks around duct-tape. 4. Add 1x2 wood strips Cable Lock 3. Baffle filters Models: AK7000, AK7036, AK7042 Page 4 Models: AK7000, AK7036, AK7042 Page 5...
  • Page 4 3. Mount the 3-1/4”x10” starting collar on top of 5. Mount starting collar (provided) at rear discharge transition piece with remaining screws. opening with gasket. Models: AK7000, AK7036, AK7042 Page 6 Models: AK7000, AK7036, AK7042 Page 7...
  • Page 5: Controls And Features

    Should you wish to lockout the touchless control for cleaning or safetely, an electric toggle switch is located inside the range hood (behind the baffle filters on the right hand side of the range hood) Toggle between I (on) or 0 (off). Models: AK7000, AK7036, AK7042 Page 8 Models: AK7000, AK7036, AK7042...
  • Page 6: Warranty

    Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr's Authorized Agents. OPTIONAL ACCESSORIES What is Not Covered: Consumable parts such as light bulbs, filters, and fuses.
  • Page 7 TO OBTAIN SERVICE UNDER WARRANTY or any Service Related Questions, please call: 1-888-880-8368 Have your product proof of purchase with date ready for warranty issues. Or write to: Zephyr Corporation Service and Warranty Department 395 Mendell Street San Francisco, CA 94124...

This manual is also suitable for:

Ak7036Ak7042