DMP Plus Series C V / C V AT – Patton POTS

3.0 Configuring DMP Plus Series C V (AT) VoIP Lines

VoIP configuration of the DMP Plus Series is handled exclusively through a web interface,
served from the device itself. The VoIP landing page is accessed through an address of the
format -
http://192.168.254.254/www/voip.html
- where 192.168.254.254 in this example is the default IP address on LAN 1 of the DMP Plus
Series device.
Line 1 will be configured as a SIP to POTS connection

3.1 Network Interface Configuration

Need to make sure that the LAN 1 and LAN 2 IP subnets (IP address / Subnet) do not overlap.
The default subnet mask on LAN 1 of 255.255.0.0 needs to be changed to 255.255.255.0
The LAN 1 IP interface will be used for Setup and control. These settings can be changed per
your application.
1. Click on the Network tab followed by Interface tab
2. Under the LAN 1 Network interface:
a. IP address Mode:
b. IP address:
c. Subnet Mask:
d. Gateway:
3. Click Apply after making any changes
a. The Network interface will restart the VoIP services on the device.
4. After the network interface has restarted
Static
192.168.254.254
255.255.255.0
0.0.0.0