Base stations
Base station synchronisation
DECT level 1 is the highest level and may appear only once in each cluster. A base station always synchronises
itself with a base station that has a better sync level. If it sees several base stations with a better sync level, it
synchronises itself with the base station that has the strongest signal. If it does not see any base station with a
higher sync level, it cannot synchronise.
 Mark the LAN Master check box, if the base station should act as LAN master.
If synchronisation via LAN is used, there must be one base station acting as LAN master.
Currently the LAN master can only be configured on DECT level 1.
 From the Sync Slave option menu select whether the base station is to be synchronised via DECT or via LAN.
For the Sync master leave this column empty.